The cart is empty.
Dealers. First. Always.
DWG

CU-8R Talk-A-Phone Recess-Mounted Area of Rescue Command Unit with 8 Station Capacity

SKU: CU-8R
  • Fully compliant with the IBC §1007, ADAG §7, ICC A117.1, and NFPA 72 §24.5.3
  • Accommodates up to 8 ADA compliant Area of Rescue Stations
  • Stations are powered by Command Unit
  • LEDs on Command Unit indicate calling Station and line status
  • On-site calling requires no outside phone lines
  • Off-site calling requires only one phone line for up to 8 Stations: line seizure eliminates need for dedicated phone line
  • Blinking LEDs indicate Stations that are waiting to be answered. When first call is completed, 2nd call is automatically placed, phone rings and strobe/siren is activated
  • Siren is activated when Emergency call is first detected, shuts off when call has been answered
More details...
MSRP Price: $4,310.00
Online Price: $4,310.00
Save to my Wish List
Product Details

Area of Rescue/Refuge (AOR) Flush Mount Command Unit (model CU-8R) is part of Talkaphone's total AOR solution that accommodates up to 8 ADA-compliant Area of Rescue/Refuge stations.
Talkaphone's complete AOR system is fully compliant with the IBC §1007, ADAG §7, ICC A117.1, and NFPA 72 §24.5.3. It consists of a Command Unit, a selected number of AOR stations (flush or surface mounted), and AOR signage to accommodate the selected number of AOR stations. The ADA-compliant AOR stations are powered by the Command Unit using one twisted-shielded pair cable from each AOR station to the Command Unit.


Specifications


  • Sound - Sounder ranges from 90 to 100 dBA, has 8 sound options
  • Construction - 16 guage #4 brushed stainless steel cabinet, acrylic windows
  • Dimensions (WxDxH) - 12.62 x 3.19 x 24.12 in. (321 x 81 x 613 mm)
  • Weight - 59 lbs. (26.8 kg)
  • Mounting - Recess mounts, strobe/sounder mounts to standard 4” square box. For surface mount version, order model CU-8
  • Communication - Lighted phone with 12-key pad receives and selectively originates calls
  • Power Source - Stations receive power from Command Unit, powered by UPS. UPS requires 120 VAC.
  • Wiring - 1 twisted, shielded pair per station not to exceed 25 ohms resistance
  • Lighting - Strobe is rated at 15 candela, flashes once per second
  • Environment - Command Unit is for indoor use, outdoor Area of Rescue Stations are available

CU-8R Specifications PDF