The cart is empty.
Dealers. First. Always.
DWG

EFLOW4NA8D Altronix Eight 8 PTC Outputs Power Supply/Charger with Multi-Output Access Power Controllers

SKU: EFLOW4NA8D
  • Eight (8) independently controlled outputs.
  • Eight (8) auxiliary power outputs (unswitched).
  • Output fuses are rated @ 3.5A.
  • Filtered and electronically regulated outputs.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
More details...
Ordering Notes: Dealers Only
MSRP Price: $590.00
Web Price: $421.00
Save to my Wish List
Product Details

eFlow4NA8D distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.


Specifications


Input

  • Voltage - 120VAC, 60Hz.
  • Input fuse - Varies, see Reference Chart.

Outputs

  • Class 2 Rated power-limited PTC Protected Outputs (auto-resettable).
  • Voltage - 12VDC or 24VDC, see Reference Chart.
  • Current - Varies, depending on the model.
  • Protection - PTC 2.5A.
  • Auxiliary - 3.5A (unswitched).
  • Other - Overvoltage protection Filtered and regulated outputs.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (1 or 2 within enclosure). 18AH / 40 AH / 65 AH requires separate enclosure).
  • Type - Sealed lead acid or gel type.
  • Fuse Rating - Varies, see Reference Chart.
  • Failover - Upon AC loss, instantaneous.

Supervision

  • AC Failure - Form “C"contacts.
  • Battery - Form “C"contacts.
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the eight (8) outputs.
  • EOL - 10K Resistor.

Indicators (LED)

  • Input - 120VAC is present.
  • DC Output - Powered.
  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered.

Agency Listings

  • UL - UL294 Access Control System Units.
  • cUL - ULC S319-05 Electronic Access Control Systems.Class I Equipment; CSA C22.2 No.205 - Signal Equipment
  • CSFM - California State Fire Marshall Approved.
  • CE - European Conformity

Physical and Environmental

  • Dimensions (H x W x D) - 15.5"x 12"x 4.5"(393.7mm x 304.8mm x 114.3mm
  • Product Weight - 8.65 lbs. (3.92 kg)
  • Shipping Weight - 9.95 lbs. (4.51 kg)
  • Operating temperature - 0°C to 49°C (32°F to 120°F).
  • Storage temperature - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 12VDC - 25 BTU/Hr, 24VDC - 50 BTU/Hr.

EFLOW4NA8D Specifications PDF

EFLOW4NA8D Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900