The cart is empty.
Dealers. First. Always.
DWG

AL600ULACMCB Altronix 8 Output PTC Power Supply/Charger w/ Controller and Enclosure 12VDC or 24VDC @ 6 Amp

SKU: AL600ULACMCB
  • Eight (8) auxiliary power outputs (unswitched).
  • Output PTCs are rated @ 2.5A.
  • Filtered and electronically regulated outputs.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
  • UL Listed in the U.S. and Canada.
  • Lifetime Warranty / Made in the U.S.A.
  • Alarm output relay indicates that FACP input is triggered.
More details...
Ordering Notes: Dealers Only
MSRP Price: $618.00
Online Price: $441.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Altronix ACMCB series distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into eight (8) independently con-trolled 12VDC or 24VDC Class 2 Rated power-limited PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm discon-nect feature is individually selectable for any or all of the eight (8) outputs.


Specifications


Inputs

  • Voltage - 115VAC, 60Hz.
  • Input Fuse - Varies, see Reference Chart.

Output

  • Class 2 Rated power-limited PTC Protected Outputs (auto-resettable)
  • Voltage - 12VDC or 24VDC, see Reference Chart.
  • Current - Varies, depending on the model.
  • Protection - PTC 2.5A.
  • Auxiliary - 3.5A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated outputs.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (1 or 2 within enclosure). 18AH / 12VDC (requires larger "J" enclosure). 40 AH / 65 AH (requires separate enclosure).
  • Fuse Rating - 15A @ 32VDC AL600ULACMCB(J) does not have a battery fuse.
  • Type - Sealed lead acid or gel type.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Latching or non-latching, individually selectable for any or all of the eight (8) outputs.

Supervision

  • AC Failure - Form "C" contacts.
  • Battery - Form "C" contacts.

Indicators (LED)

  • Input - 115VAC is present.
  • DC Output - Powered.
  • Battery - Discharged or not connected.
  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered.

Agency Listings

  • All Models
    • UL
      • UL294 - Access Control System Units.
    • cUL
      • CSA C22.2 No.205 - Signal Equipment.
  • AL400ULACMCB(J), AL600ULACMCB(J) only
    • CSFM - California State Fire Marshal Approved.

Physical and Environmental

  • Dimensions (H x W x D) - 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm).
  • Product Weight / Shipping (approx.)
    • Product Weight - 10.3 lbs. (4.67 kg)
    • Shipping Weight - 11.6 lbs. (5.26 kg)
  • Temperature
    • Operating - 0°C to 49°C (32°F to 120°F).
    • Storage - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.)
    • 12VDC - 37
    • 24VDC - 74

AL600ULACMCB Spec Sheet