The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL77D Altronix 16 Output PTC Power Supply/Charger w/ Controller and Enclosure 24VDC @ 9.7Amp

SKU: MAXIMAL77D
  • Sixteen (16) independently controlled Fail-Safe and/or Fail-Secure power outputs.
  • Sixteen (16) auxiliary power outputs (unswitched).
  • Output PTCs are rated @ 2.5A
  • Filtered and electronically regulated outputs.
  • Supervision: AC Fail, Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input, b) Polarity reversal input from FACP signaling circuit
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,728.00
Web Price: $1,234.00
Save to my Wish List
Product Details

Maximal Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC Class 2 Rated PTC protected power-limited autoresettable outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc.


Specifications


Input

  • Voltage - 115VAC, 60Hz
  • Fusing - Varies, see Reference Chart

Outputs

  • Sixteen (16) Class 2 Rated PTC Protected Power-limited Outputs (auto-resettable)
  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, see Reference Chart
  • Protection - PTC 2.5A.
  • Auxiliary - 2A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated Outputs.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC Maximal33 does not have a battery fuse.
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs.

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts

Indicators (LED)

  • Input - 115VAC is present
  • DC Output - Powered
  • Battery - Discharged or not connected
  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered

Agency Listings

  • UL - UL294 - Access Control System Units
  • cUL - c22.2 No.205-M1983 - General Signaling Equipment
  • CSFM - California State Fire Marshall Approved.

Physical and Environmental

  • Dimensions (H x W x D) - 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.8mm)
  • Product Weight - 33.4 lbs. (15.2 kg)
  • Shipping Weight - 40.4 lbs. (18.3 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/- 5%
  • BTU/Hr (approx.) - 24VDC - 238