The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL1R Altronix 16 Output Fused Rack Mount Power Supply/Charger w/ Controller 12VDC @ 4Amp or 24VDC @ 3Amp

SKU: MAXIMAL1R
  • Eight (8) or Sixteen (16) independently controlled fuse protected 12VDC and/or 24VDC outputs.
  • Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs
  • Thermal and short circuit protection with auto reset
  • Supervision - AC Fail, Low Battery
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the outputs
  • Fire Alarm disconnect input options - Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
  • Lifetime Warranty / Made in the U.S.A
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the outputs.
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,086.00
Web Price: $776.00
Save to my Wish List
Product Details

Maximal Rack Mount Series units distribute and switch power to access control systems and accessories. They convert a 115VAC 50/60Hz input into eight (8) or sixteen (16) independently controlled 12VDC and/or 24VDC fuse protected outputs. Outputs are activated by a normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.


Specifications


Input

  • Voltage - 115VAC, 50/60Hz.
  • Fusing - Varies, See Reference Chart.

Outputs

  • Voltage - 12VDC and/or 24VDC, see Reference Chart.
  • Current - Varies, see Reference Chart.
  • Protection - Fused 2.5A.
  • Other - Overvoltage protection, Filtered and regulated outputs.

Back-up Battery(separate enclosure is required)

  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC (Maximal1RH and Maximal1R); Maximal3RH, Maximal3R, and Maximal33R do not have a battery fuse.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the outputs.

Supervision

  • AC Failure - Form “C” contacts.
  • Battery - Form “C” contacts.

Indicators (LED)

  • Input - Illuminated ON/Reset Switch.
  • Output - Individual Output Status LEDs located on the front panel.

Physical and Environmental

  • Dimensions (H x W x D) - 3.25” x 19.125” x 8.5” (82.55mm x 485.78mm x 215.9mm).
  • Product Weight - 10.7 lbs. (4.85 kg)
  • Shipping Weight - 12.7 lbs (5.76kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF).
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF).
  • BTU/Hr. (approx.) - 12VDC - 25, 24VDC - 37, 12 and 24VDC - N/A

MAXIMAL1R Specifications PDF

MAXIMAL1R Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In