EXHC003R Videotec Explosion Proof Housing w/ Triple Heater and Glass Protection Device 24VAC

SKU: EXHC003R
  • Solid anticorodal aluminium construction
  • Epoxypolyester powder painting, RAL7032
  • IP66
  • 2 holes for cable glands 3/4" NPT
  • Version with device for the protection of the glass installed on the front of the housing (EXHD)
  • Version available with reinforced heater 24Vac and special painting RAL7001 for temperature application down to -40°C (-40°F) (mod.EXHC003R)
  • Supplied with heater. Sunshield as option.
  • Internal usable area (WxHxL): 100x100x280mm (3.9x3.9x11in)
More details...
MSRP Price: $3,073.00
Web Price: $2,305.00
Save to my Wish List
Product Details

Explosion-proof housing with the same specifications as the EXHC series but fitted with a patented device for the protection of the glass which gives clear vision in dirty environments. It consists of a connection flange with the housing, a closing flange and an explosion-proof central body containing a rugged transparent glass, a continuous current motor powered in 24Vac, two rollers and a transparent Mylar film, installed just in front of the glass. The motor drives, through four pinions with gear  rim, the winding for recovering the dirty Mylar film, while at the same time the other winding installed on the opposite side releases the clean film.

NOTE: the control unit of the glass protection device is not supplied with the EXHD.

The transparent Mylar film, 80mm wide and 18m long, allows 350 steps. When the film is dirty, the operator will activate the motor shifting the film to obtain a clean camera picture (the step for allowing the complete shift of the dirty film is about 50mm). The end of the Mylar film will be indicated to the operator through marks printed on the last 50cm of the film.

  • Solid anticorodal aluminium construction
  • Epoxypolyester powder painting, RAL7032
  • IP66
  • 2 holes for cable glands 3/4" NPT
  • Version with device for the protection of the glass installed on the front of the housing (EXHD)
  • Version available with reinforced heater 24Vac and special painting RAL7001 for temperature application down to -40°C (-40°F) (mod.EXHC003R)
  • Supplied with heater. Sunshield as option.
  • Internal usable area (WxHxL): 100x100x280mm (3.9x3.9x11in)

Specifications


General

  • Non-corrosive die-cast aluminum (anticorodal)
  • Bicomponent polyurethane enamel with orange peel effect, RAL7032
  • Special painting for low temperature, blue colour RAL7001 (EXHC003R, EXWBJ00R, EXBJ00R).  Resistant to stress cracking, adverse weather conditions, detergents, salt-spray and typical airborne pollutants.

Mechanical

  • 2 inputs 3/4” NPT for cables
  • External dimensions
    • EXHC Ø 210mmx427.5mm (8.2x16.8in)
    • EXHD Ø 250x573.5mm (9.8x22.6in)
  • Internal dimensions
    • EXHC Ø 180x380mm (7x14.9in)
    • EXHD Ø 180x460mm (7x18.1in)
  • Internal usable area
    • EXHC 100x100x280mm (3.9x3.9x11in)
    • EXHD 100x100x280mm (3.9x3.9x11in)
  • Glass window
    • EXHC Ø 114mm (4.5in)
    • EXHD 70x56mm (2.7x2.2in)
  • Glass protection device
    • Glass protection device Ø 250x140mm (9,8x5,5in)
    • Mylar film 80mm (3.1in) wide and 18m (59ft) length, 350 shifting steps, marks printed on the last 50cm (19in)

Electrical

  • Heater Ton 10°C±4°C (50°F±7°F) Toff 25°C±3°C (77°F±5°F)
    • IN 24Vac, consumption 20W max
    • IN 230Vac, consumption 20W max (only for EXHC200)
  • Reinforced heater Ton 10°C±4°C (50°F±7°F) Toff 25°C±3°C (77°F±5°F)
    • IN 24Vac, consumption 20W max
    • 3 resistors in the housing, consumption 60W max
  • Glass protection device - 24Vac/Vdc, consumption 2W max
  • Devices to install inside the housing
    • Camera equipped with lens with max total power of 20W
    • Power supply max 24Vac or 230Vac

Environment

  • Indoor / Outdoor
  • Operating temperature with heater: -20°C / +50°C (-4°F / +122°F)
  • Operating temperature with reinforced heater: -40°C/+50°C (-40°F/+122°F)
  • Always refer to the temperature in the marking.

Certifications

  • ATEX (EN 60079-0: 2010, EN 60079-1: 2008, EN 60079-31: 2010)
    • b II 2G Ex d IIC T6 Gb
    • b II 2D Ex t IIIC T85 °C Db IP66
  • c 0044: notify number from competent body
  • IECEx (IEC 60079-0: 2007, IEC 60079-1: 2007, IEC 60079-31: 2008)
    • Ex d IIC T6 Gb
    • Ex t IIIC T85 °C Db IP66
  • GOST-R 1 Ex d IIC T6 и DIP A21 TA T6
  • CNEX Ex d IIC T6 DIP A21 TA T6

EXHC003R Specifications PDF

Check out some additional items that you may need to purchase with this product:
Check the check boxes next to the additional products that you would like to add to the shopping cart, then click on the "Add to Cart" button above. A check box is not shown if a product requires that you select an option or fill out a field. () indicates a required accessory.

Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In