The cart is empty.
Dealers. First. Always.
DWG

EFLOW104NX16 Altronix Sixteen 16 Fused Outputs Power Supply/Charger

SKU: EFLOW104NX16
  • Available with 1, 8 or 16 outputs
  • Fused outputs or PTC protected Class 2 power-limited outputs
  • Additional aux. Class 2 power-limited output rated @ 1A
  • Overvoltage protection
  • Fire alarm disconnect
  • Supervision: AC Fail, Battery Fail and Battery Presence, Low power shutdown
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
More details...
Ordering Notes: Dealers Only
MSRP Price: $668.00
Online Price: $477.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Altronix eFlow104NX16 is a power supply/charger that converts a 120VAC 60Hz input into sixteen fuse protected 24VDC outputs with a total of 10A max. The unit includes an unswitched aux. output. It also offers a suite of features that includes fire alarm disconnect, over voltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.


Specifications


Input

  • Voltage - 120VAC, 60Hz, 4.5A max.
  • Fusing - 6.3A / 250V.

Outputs

  • Voltage - 24VDC.
  • Current - 10A continuous max.
  • Protection - Fused 2.5A / PTC 2A.
  • Auxiliary - Class 2 power-limited @ 1A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated.

Back-up Battery (not included)

  • Capacity - 7AH / 12VDC (2 within enclosure). 12AH / 12VDC (requires larger “X" enclosure). 40AH, 65AH (requires separate enclosure).
  • Type - Sealed lead acid or gel type.
  • Fuse Rating - 15A / 32VDC.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching.
  • EOL - 10K Resistor.

Supervision

  • AC Failure - Form "C" contacts.
  • Battery - Form "C" contacts.
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units depending on the power supply). Prevents deep battery discharge.

Indicators (LED)

  • Input - 120VAC is present.
  • DC Output - Powered.

Agency Listings

  • UL
    • UL294 - Access Control System Units.
    • UL603 - Power Supplies for Use with Burglar-Alarms Systems.
    • UL1481 - Power Supplies for Fire Protective Signaling Systems.
  • cUL - ULC-S318-96 - Power Supplies for Burglar Alarm Systems. Also suitable for Access Control.
  • CSFM - California State Fire Marshall Approved.
  • CE - European Conformity

Physical and Environmental

  • Dimensions (H x W x D) - 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm).
  • Product Weight - 8.95 lbs. (4.06 kg)
  • Shipping Weight - 10.05 lbs. (4.56 kg)
  • Operating Temperature - 0°C to 49°C (32°F to 120°F).
  • Storage Temperature - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 123 BTU/Hr.

EFLOW104NX16 Specifications PDF