The cart is empty.
Dealers. First. Always.
DWG

EFLOW104NA8D Altronix Eight 8 PTC Outputs Power Supply/Charger with Multi-Output Access Power Controllers

SKU: EFLOW104NA8D
  • Eight (8) independently controlled outputs
  • Output options: Eight (8) Fail-Safe and/or Fail-Secure power outputs, Eight (8) form “C” 5A rated relay outputs, Any combination of the above
  • Eight (8) auxiliary power outputs (unswitched)
  • Output PTCs are rated @ 2.5A
  • Filtered and electronically regulated outputs
  • Supervision: AC Fail, Battery Fail and Battery Presence, Low power shutdown
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Alarm output relay indicates that FACP input is triggered
More details...
Ordering Notes: Dealers Only
MSRP Price: $722.00
Online Price: $516.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Altronix eFlow104NA8D unit distribut and switch power to access control systems and accessories. It converts a 120VAC 60Hz input into eight (8) independently controlled 24VDC PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.


Specifications


Input

  • Voltage - 120VAC, 60Hz.
  • Fusing - Varies, see Reference Chart.

Outputs

  • Class 2 Rated power-limited PTC Protected Outputs (auto-resettable)
  • Voltage - 12VDC or 24VDC, see Reference Chart.
  • Current - Varies, depending on the model.
  • Protection - Fused 3.5A.
  • Auxiliary - 3.5A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (1 or 2 within enclosure).18AH / 40 AH / 65 AH
  • Type - Sealed lead acid or gel type.
  • Fuse Rating - Varies, see Reference Chart.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the eight (8) outputs
  • EOL - 10K Resistor.

Supervision

  • AC Failure - Form "C" contacts.
  • Battery - Form "C" contacts.
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units depending on the power supply). Prevents deep battery discharge.

Indicators (LED)

  • Input - 120VAC is present.
  • DC Output - Powered.
  • Relays - Individual LEDs indicate outputs are triggered (relays energized)
  • FACP - Indicates FACP disconnect is triggered

Agency Listings

  • UL - UL294 - Access Control System Units.
  • cUL - ULC-S319-05 - Electronic Access Control Systems.Class I Equipment, CSA C22.2 No.205 - Signal Equipment.
  • CSFM - California State Fire Marshall Approved.
  • CE - European Conformity

Physical and Environmental

  • Dimensions (H x W x D) - 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm).
  • Product Weight - 8.9 lbs. (4.04 kg)
  • Shipping Weight - 10.2 lbs. (4.63 kg)
  • Operating Temperature - 0°C to 49°C (32°F to 120°F).
  • Storage Temperature - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 24VDC - 123 BTU/Hr.

EFLOW104NA8D Specifications PDF

EFLOW104NA8D Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In