MAXIMAL33FD Altronix Access Power Controller Two 2 eFlow6 16 PTC Outputs

SKU: MAXIMAL33FD
  • Sixteen (16) independently controlled (16) Fail-Safe and/or Fail-Secure power outputs.
  • Sixteen (16) auxiliary power outputs (unswitched).
  • Output PTCs are rated @ 2.5A.
  • Filtered and electronically regulated outputs.
  • Supervision - AC Fail, Battery Fail and Battery Presence, Low power shutdown.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Fire Alarm disconnect input options - Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,732.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Maximal3FD Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC power-limited PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc.


Specifications


Input

  • Voltage - 115VAC, 60Hz.
  • Fusing - Varies, see Reference Chart.

Outputs

  • Voltage - 12VDC or 24VDC, see Reference Chart.
  • Current - Varies, see Reference Chart.
  • Protection - PTC 2.5A.
  • Auxiliary - 2.5A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure).
  • Type - Sealed lead acid or gel type.
  • Fuse Rating - Varies, see Reference Chart.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs.
  • EOL - 10K Resistor.

Supervision

  • AC Failure - Form "C" contacts.
  • Battery - Form"C" contacts.
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.

Indicators (LED)

  • Input - 120VAC is present.
  • DC Output - Powered.
  • Battery - Discharged or not connected.

Indicators (LED) (cont’d)

  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered.

Agency Listings

  • UL - UL294 Access Control System Units.
  • cUL - ULC-S319-05 Electronic Access Control Systems Class I equipment, CSA C22.2 No.205 - Signal Equipment.
  • CSFM - California State Fire Marshall Approved.
  • CE - European Conformity.

Physical and Environmental

  • Dimensions (H x W x D) - 26" x 19" x 6.25" (660.4mm x 482.6mm x 158.75mm).
  • Product Weight - 32.6 lb. (14.8 kg)
  • Shipping Weight - 39.6 lb. (18 kg)
  • Operating Temperature - 0°C to 49°C (32°F to 120°F).
  • Storage Temperature - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 12VDC - 65, 24VDC - 138, 12 and 24VDC - 101

MAXIMAL33FD Specifications PDF