MAXIMAL75F Altronix Access Power Controller Single eFlow104 Plus SingleeFlow102 16 Fused Outputs

SKU: MAXIMAL75F
  • Sixteen (16) independently controlled outputs.
  • Output options: Sixteen (16) Fail-Safe and/or Fail-Secure power outputs, Sixteen (16) form “C” 5A rated relay outputs, Any combination of the above
  • Sixteen (16) auxiliary power output (unswitched).
  • Output fuses are rated @ 3.5A
  • Filtered and electronically regulated outputs.
  • Supervision: AC Fail, Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non latching) is individually selectable for any or all of the sixteen (16) outputs
  • Alarm output relay indicates that FACP input is triggered
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,800.00
Online Price: $1,286.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

MaximalF Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 120VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form “C” contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc.


Specifications


Input

  • Voltage - 120VAC, 60Hz
  • Input Fuse - Varies, see Reference Chart

Outputs

  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, see Reference Chart
  • Protection - Fused 3.5A.
  • Auxiliary - 2.5A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated outputs.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Fuse Rating - Varies, see Reference Chart.
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs
  • EOL - 10K Resistor.

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge

Indicators (LED)

  • Input - 120VAC is present
  • DC Output - Powered

Indicators (LED) (cont’d)

  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP- Indcates FACP disconnect is triggered.

AgencyListings

  • UL - UL294 - Access Control System Units
  • cUL - ULC-S319-05 - Electronic Access Control Systems Class I equipment, CSA C22.2 No.205 - Signal Equipment.
  • CSFM - California State Fire Marshall Approved
  • CE - European Conformity.

Physical and Environmental

  • Dimensions (H x W x D) - 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm)
  • Product Weight - 32.6 lbs. (14.8 kg)
  • Shipping Weight - 39.6 lbs. (18 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/- 5%
  • BTU/Hr (approx.) - 12 and 24VDC - 177

MAXIMAL75F Specifications PDF