The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL75FD Altronix Access Power Controller Single eFlow102 Plus Single eFlow104 16 PTC Outputs

SKU: MAXIMAL75FD
  • Sixteen (16) independently controlled Fail-Safe and/or Fail-Secure Class 2 Rated PTC protected power-limited outputs
  • Sixteen (16) auxiliary power output (unswitched).
  • Output PTCs are rated @ 2.5A
  • Filtered and electronically regulated outputs.
  • Supervision: AC Fail, Battery Fail and Battery Presence, Low power shutdown
  • Fire Alarm disconnect (latching or non latching) is individually selectable for any or all of the sixteen (16) outputs
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input, b) Polarity reversal input from FACP signaling circuit
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,800.00
Online Price: $1,286.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

MaximalFD Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 120VAC, 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.


Specifications


Input

  • Voltage - 120VAC, 60Hz
  • Input Fuse - Varies, see Reference Chart

Outputs

  • Class 2 Rated power-limited PTC Protected Outputs (auto-resettable)
  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, see Reference Chart
  • Protection - Fused 2.5A.
  • Auxiliary - 3.5A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated outputs.

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (Up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Fuse Rating - Varies, see Reference Chart.
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs
  • EOL - 10K Resistor.

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge

Indicators (LED)

  • Input - 120VAC is present
  • DC Output - Powered

Indicators (LED) (cont’d)

  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP- Indcates FACP disconnect is triggered.

AgencyListings

  • UL - UL294 - Access Control System Units
  • cUL - ULC-S319-05 - Electronic Access Control Systems Class I equipment, CSA C22.2 No.205 - Signal Equipment.
  • CSFM - California State Fire Marshall Approved
  • CE - European Conformity.

Physical and Environmental

  • Dimensions (H x W x D) - 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm)
  • Product Weight - 32.6 lbs. (14.8 kg)
  • Shipping Weight - 39.6 lbs. (18 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/- 5%
  • BTU/Hr (approx.) - 12 and 24VDC - 177

MAXIMAL75FD Specifications PDF

MAXIMAL75FD Manual