LFHSHR3-CO Cooper Wheelock Exceder LED3 520 Hz Low Frequency Sounder Strobes - CO
|
|
|
SKU: LFHSHR3-CO
- Meets dual low frequency sounder codes for sleeping rooms in a single device
- NFPA 72 for fire alarm
- NFPA 720 for CO alarm
- 4 Settings in 1 device
- T3 (fire)
- T4 (CO)
- Continuous (Coded)
- T3/T4
- Energy efficient
- Patented LED technology provides industry’s lowest current draw
- Low-profile design
- Smallest footprint with sleek, modern aesthetics
- 110 or 177 candela setting (dependent on model)
- Easy-to-install
- Finger slide switches--No tools needed for setting changes
- Built-in level adjustment feature and snap-on grille cover
- IN/OUT screw terminals using #12 to #18 AWG wires
- Mounting Options: Trim plate (LFTP) for single-gang backbox included in all LFHNK3/LFHSK3/LFHSH3 models; Exceder LSPKBB backboxes and 4” square backboxes
- Strobe synchronization components
- Meet synchronizing standards with Wheelock’s DSM Sync Modules or Power Supplies
More details...MSRP Price: $150.61 Online Price: $120.00
|
DWG Dealer Price : ---
Dealers - click here to set up your dealer account today.
Existing DWG Customers - Log In to view your current dealer pricing.
|
|
|
LFHSHR3-CO Cooper Wheelock Exceder LED3 520 Hz Low Frequency Sounder Strobes - CO
|
|
|
|
Product Details
|
Eaton has developed the Wheelock Exceder LED3 Low Frequency Sounder Strobes (LFHSK3/LFHSH3) and Sounders (LFHNK3) to meet the National Fire Protection Association (NFPA) low frequency sounder requirements for sleeping rooms Specifications
Physical - Material - Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating
- Weight - 1.10 lbs.
- Lens - Light Emitting Diode (LED) in a rugged Lexan lens
- Dimensions - 6.23”H x 4.69” W x 1.77” D (with LFTP trim plate)
- Operating Temperature - Indoor: 32°F to 122°F (0°C to 50°C) and maximum humidity of 93%
Mounting & Wire Connections - Mounting (indoor only) - Wall-mount applications for sounder strobe (LFHSK3/LFHSH3); Wall and ceiling-mount applications for the sounder only model (LFHNK3). Trim plate for single-gang backbox included in all LFHNK3/LFHSK3/LFHSH3 models; Exceder LSPKBB backboxes and 4” square backboxes
- Wire Connections - #12 through #18 AWG
Power & General - Operating voltage - 24 VDC: 16 - 33 VDC
- Strobe Output Rating - UL 1971: 110 candela output (LFHSK3 models)/ 177 candela output (LFHSH3 models)
- Strobe Flash Rate - Strobes are designed to flash at 1 flash per second
- Synchronization Models - Strobes can be synchronized with Wheelock’s DSM Sync Modules, PS Power Supplies, using Wheelock patented sync protocol
- Temporal Audible Pattern - Continuous, Code 3, Code 4 or Code 3/Code 4 Sync Control. The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. The Code 4 temporal pattern (four cycles of 100 milliseconds ± 10 percent “on” and 100 milliseconds ± 10 percent “off,” followed by 5 seconds ± 10 percent “off)is specified by NFPA 720
LFHSHR3-CO Specification Pdf
|
|
|