The cart is empty.
Dealers. First. Always.
DWG

MVXT2Q0SAZ00B Videotec 9mm 25FPS @ 336 x 256 Outdoor Uncooled Thermal IP Security Camera 12-24VDC/24VAC with Cable Gland and 13ft Armored Cable

Videotec manufacturers a complete line of general purpose, industrial, and explosion proof security camera housings, as well as illuminators all available from DWG.

SKU: MVXT2Q0SAZ00B
  • Certifications for use in Zones 1 and 2, IIC T5 and T6 Group (Gas) and in Zones 21 and 22, IIIC T100°C and T85°C Group (Dust)
  • Marine Certification: Lloyd's Register Marine Type Approval
  • AISI 316L stainless steel construction
  • External shot peened and electro-polished surfaces
  • Analogue or IP (ONVIF Profile S, ONVIF Profile Q, ONVIF Thermal Service) versions
  • Thermal cameras
    • Sensor : Uncooled VOx microbolometer
    • Lenses : 9mm, 13mm, 19mm, 25mm, 35mm, 50mm, 60mm
    • Resolution : 336x256 or 640x512
  • 1 alarm input and 1 relay output
  • 4m (13ft) / 10m (32.8ft) preinstalled armoured multipolar cable with cable gland or, alternatively, with 4m (13ft) / 10m (32.8ft) cable tail (for installation with conduit, conduit sealing fitting and conduit not included)
More details...
MSRP Price: $15,262.00
Online Price: $11,446.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

The explosion-proof camera MAXIMUS MVXT is perfect for efficient and preventive video surveillance and control of processes in hazardous environments where the atmosphere is potentially explosive due to the presence of inflammable gases or dust, typical of the Oil&Gas, marine or industrial sectors.


Specifications


Technical Data


General

  • AISI 316L stainless steel construction
  • External shot peened and electro-polished surfaces
  • Silicone O-ring seals
  • Configuration via OSM

Mechanical

  • Sunshield
  • Unit weight
    • 8.5kg (18.7lb) (housing with 4m (13ft) multi-polar cable shield)
    • 12kg (26.5lb) (housing with 10m multi-polar cable shield)

Cable Glands

  • Cable entry : 1 hole, 3/4", NPT
  • Cable gland Ex db 3/4"NPT and 4m/10m (13ft/33ft) preinstalled multipolar armored cable or with 4m/10m (13ft/33ft) cable tail (for installation with conduit, conduit sealing fitting and conduit not included)

Housing's window

  • Germanium window (big grid)
    • Usable diameter : 57mm (2.2in)
    • Thick : 10mm (0.4in)
    • External treatment : antiscratch (Hard Carbon Coating - DLC), antireflection
    • Internal treatment : antireflection
    • Spectral range : from 7.5μm up to 14μm
    • Medium transmittance (from 7.5μm up to 11.5μm) : 87.3%
    • Medium transmittance (from 11.5μm up to 14μm) : 67.3%
  • Germanium window (small grid)
    • Usable diameter : 40mm (1.6in)
    • Thick : 8mm (0.3in)
    • External treatment : antiscratch (Hard Carbon Coating - DLC), antireflection
    • Internal treatment : antireflection
    • Spectral range : from 7.5μm up to 14μm
    • Medium transmittance (from 7.5μm up to 11.5μm) : 87.5%
    • Medium transmittance (from 11.5μm up to 14μm) : 72.1%

Electrical

  • Supply voltage/Current consumption (heating switched on, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C (72°F±5°F))
    • 24Vac ±10%, 2.2A, 50/60Hz
    • 24Vdc ±5%, 2.2A
    • 12Vdc ±5%, 3.5A
  • Armoured cable
    • Eexternal diameter = 20.00 ± 0.50mm (0.79±0.20in)
    • Diameter under armature = 15.20mm (0.60in)
    • Colour : Black RAL9005
  • Armoured cable composition
    • 3 x 2.5mm²
    • 7 x 0.34mm²
    • 4 x 2 x 0.22mm² (IP-based version, cat. 5E)
    • 1 x coax 75ohm RG179 (analog version)
  • Cable tail composition
    • 3 x 2.5mm², rated external diameter = 8.7mm (0.34in)
    • 7 x 0.34mm², rated external diameter = 6.4mm (0.25in)
    • 4 x 2 x 0.21mm², (IP-based version, cat. 5E), rated external diameter = 6.7mm (0.26in)
    • 1 x coax 75ohm RG59 (analog version), rated external diameter = 4.9mm (0.19in)

Network

  • Only for the IP versions of the product
  • Ethernet connection: 10BASE-T/100BASE-T
  • Connector : RJ45
  • Cable length : 100m max

Serial communications

  • Only for product analogue versions
  • Serial interface
    • RS-485 line, half-duplex
    • Cable length : 1200m max
    • Addressable units : 255 (configuration via OSM)
  • Serial communication protocol
    • PANASONIC 850 : 9600baud, 19200baud
    • PELCO D : 2400baud, 9600baud
    • MACRO : 9600baud, 38400baud

Video

  • Only for the IP versions of the product
  • Video encoder
    • Communication protocol: ONVIF, Profile S and Profile Q, ONVIF Thermal Service
    • Device configuration: TCP/IPv4-IPv6, UDP/IPv4-IPv6, HTTP, HTTPS, NTP, DHCP, WS-DISCOVERY, DSCP, IGMP (Multicast), SOAP, DNS
    • Streaming : RTSP, RTCP, RTP/IPv4-IPv6, HTTP, Multicast
    • Video compression : H.264/AVC, MJPEG, JPEG, MPEG4
    • 3 independent video streams
    • Image resolution : from 160x120pixel up to 720x480pixel in 5 steps
    • Selectable frame rate from 1 to 30 images per second (fps)
    • Web Server
    • Motion Detection
    • Cybersecurity : IEEE 802.1X
    • QoS : Differentiated DSCPs for streaming and device management

I/O interface

  • I/O alarm board
    • Alarm inputs : 1
    • Relay outputs : 1 (1A, 30Vac/60Vdc max)
  • Cable lengt : 200m (656ft) max

Environment

  • For indoors and outdoors installation
  • Operating temperature
    • Cold start from -40°C (-40°F) up to +65°C (149°F)
    • Running from -50°C (-58°F) up to +65°C (149°F)
  • Relative humidity : from 5% up to 95%

Certifications

  • Electrical safety (CE) : EN60950-1, IEC60950-1, EN62368-1, IEC62368-1
  • Electromagnetic compatibility (CE) : EN61000-6-4, EN61000-3-2, EN61000-3-3, EN50130-4, EN55032 (Class A)
  • RoHS (CE) : EN50581
  • Outdoor installation (CE) : EN60950-22, ICE60950-22
  • IP protection degree (EN/IEC60529) : IP66, IP67, IP68 (2 hours, 5m (16ft)), IP69
  • Vibration test : EN50130-5, EN60068-2-6
  • UL certification (UL60950-1, CAN/CSA C22.2 No. 60950-1-07) : cULus Listed
  • Electromagnetic compatibility (North America) : FCC part 15 (Class A), ICES-003 (Class A)
  • Level of protection Type (UL50E) : 4X, 6P

Certifications - Explosion-proof applications

  • ATEX (EN 60079-0+A11, EN 60079-1, EN 60079-31)
  • IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31)
  • EAC EX (TR CU 012/2011)
  • INMETRO (ABNT NBR IEC 60079-0 + Errata 1, ABNT NBR IEC 60079-1 + Errata 1, ABNT NBR IEC 60079-31)
  • ETL listed for USA (UL 60079-0, UL 60079-1, UL 60079-31), cable tail versions
  • ETL listed for Canada (CAN/CSA-C22.2 NO. 60079-0, CAN/CSA-C22.2 NO. 60079-1, CAN/CSA-C22.2 NO. 60079-31), cable tail versions

Cerrtifications - Marine applications

  • Lloyd's Register Marine Type Approval certification (only if used with the filter accessory FM1010) : Test Specification Number 1 (ENV1, ENV2, ENV3, ENV5)
  • Electromagnetic compatibility : EN60945
  • Salty fog resistance: EN60068-2-52
  • Tested at 70°C (158°F) for 16 hours in compliance with EN60068-2-2

MVXT2Q0SAZ00B Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900