FPO150-B100C82D8PE6M/T8-C LifeSafety Power ProWire Mercury 8 Door 4 Amp 12VDC 4 Amp 24VDC 8 Lock and 16 Auxiliary Distribution Outputs Access Control Power Supply in UL Listed Indoor 23" W x 30" H x 6.5" D Electrical Enclosure
|
|
|
SKU: FPO150-B100C82D8PE6M/T8-C
- Guarantees uniform installations across an enterprise
- Pre-installed wire harness for panel power, lock control, faults and tamper switch
- Point to point wiring; labeled, color coded, twisted pair, shielded communication
- Tie wrap or wire duct cable management options
- Managed systems monitor power, batteries and sixteen outputs
- UL294, ULC S319 joint LSP / Mercury integrated listing
More details...MSRP Price: $2,097.00 Online Price: $1,399.00
|
DWG Dealer Price : ---
Dealers - click here to set up your dealer account today.
Existing DWG Customers - Log In to view your current dealer pricing.
|
|
|
FPO150-B100C82D8PE6M/T8-C LifeSafety Power ProWire Mercury 8 Door 4 Amp 12VDC 4 Amp 24VDC 8 Lock and 16 Auxiliary Distribution Outputs Access Control Power Supply in UL Listed Indoor 23" W x 30" H x 6.5" D Electrical Enclosure
|
|
|
|
Product Details
|
These ProWire Unified Power wall mount models are single and dual voltage access power systems, precision wired for Mercury controllers. ProWire enables the specification and installation of standardized access power equipment across an enterprise for uniform operation, maintenance and servicing. The C8 or M8 control modules each provide eight access control inputs capable of voltage or dry contact activation, and eight outputs programmable for failsafe / failsecure operation at either 12 or 24 VDC and controlled by the power supply fire alarm interface. The D8 module provides eight auxiliary outputs. In dual voltage systems, each output is configurable for 12 or 24VDC operation.
Specifications
Power Supplies - FPO150 Power supply board 150W, 4A/24V
- B100 Secondard voltage module, 4A/12V class 2 power limited
- Input 120/230VAC 50/60Hz | 170 Watts (1.42A)
- Overload and short circuit protection
- Over temperature protection
- Polarized AC power supply disconnect
Battery Charging - Independent built-in charger for sealed lead-acid or gel type batteries
- Microprocessor dual rate charging of 12 or 24V battery sets
- Automatic switchover to standby battery when AC fails
- Zero voltage drop when switched over to battery backup
Supervision - AC Fault (form "C" contacts)
- System Fault (form "C" contacts)
- System Fault conditions: Low or no battery | short to earth ground | power supply failure
Distribution Modules - D8P (X2) 8 auxiliary outputs, class 2 power limited at 2.5A per output (second D8P dedicated power to Mercury controllers)
- C8 8 relay lock control outputs, fused at 3A per output
Enclosures - Size - 30.00H x 23.00W x 6.50D in. (76.20 x 58.12 x 16.50 cm)
- Weight - 47 lbs.
Wiring Suffix - T8-C - T = Tie Wrap, 8 = Door Count, C = All MR52s
Regulatory Compliance - UL / ULC - UL294, ULC S319
- CSA / FCC - CSA C22.2 #107.1 | FCC Part 15, CSFM
FPO150-B100C82D8PE6M/T8-C Specifications PDF
|
|
|