The cart is empty.
Dealers. First. Always.
DWG

FPO150-B100C8D8E4V1 LifeSafety Power Vertx 8 Door 4 Amp 12VDC and 24VDC 8 Lock and 8 Auxiliary Distribution Outputs Access Control Power Supply in UL Listed Indoor 20" W x 24" H x 6.5" D Electrical Enclosure

SKU: FPO150-B100C8D8E4V1
  • 120 or 230 VAC input
  • 12 or 24 VDC outputs
  • On board Fire Alarm Interface
  • Continuous and resettable DC
  • Eight auxiliary - class II at 2.5A each
  • Eight lock control - fused at 3A each
  • Live voltage / current reporting
  • Remote battery load testing
  • Output power cycling and abnormal operation alert
  • System / AC fault reporting
More details...
Availability: 2 to 3 Week Lead Time
Ordering Notes: Dealers Only
MSRP Price: $1,102.00
Web Price: $735.00
Save to my Wish List
Product Details

VCLASS Unified Power Solutions are engineered to house FlexPower power modules alongside HID VERTX access hardware in one compact, secure solution. This unit is a 150W dual voltage 12V and 24V DC access power system.

C8 lock control module provide eight access control inputs capable of voltage or dry contact activation, and eight outputs programmable for failsafe / failsecure operation at either 12 or 24 VDC and controlled by the integrated fire alarm interface circuit on the FPO. D8 module provides eight fused outputs and each output is configurable for 12 or 24VDC operation.


Specifications


Input Power

  • Input 120/230 VAC 50/60 Hz | 170 Watts (1.41A)
  • Overload and short circuit protection
  • Over temperature protection
  • Polarized AC power supply disconnect

Output Power

  • FPO150: 12V/12A or 24V/6A | 150 Watts
  • Outputs: Continuous (DC1) Resettable (DC2)
  • 8 auxiliary outputs, fused at 3A each
  • 8 lock control outputs, fused at 3A each
  • 120 mV output voltage ripple
  • System Efficiency: 87% | System BTU Rating: 66 BTU/Hr

Battery Charging

  • Independent built-in 2A charger for sealed lead acid or gel type batteries
  • Microprocessor dual rate charging of 12 or 24 V battery sets
  • Automatic switchover to standby battery when AC fails
  • Zero voltage drop when switched over to battery backup

Supervision

  • AC Fail (form "C" contacts)
  • System Fault (form "C" contacts) may be triggered by low/no battery, short to earth ground, power supply failure

Visual Indicators

  • AC input, DC1 and DC2 output
  • System fault | AC fault | Short to earth ground | Reverse battery polarity
  • Fire Alarm Input activated
  • B100: DC input, output and Fault
  • C8: DC input, output and Fault
  • D8: DC outputs

Regulatory Compliance

  • UL294, UL603, UL1076
  • ULC S318, ULC S319, CSA C22.2 #107.1, CSA C22.2 #60950
  • CE | CSFM Approved | FCC Part 15, Subpart B

Enclosure Dimensions

  • Size: 24.00H x 20.00W x 4.50D in. (61.00 x 51.00 x 11.50 cm)

Mounting Pattern For

  • V1000, V100, V200, V300

FPO150-B100C8D8E4V1 Specifications PDF