3008040 Potter WSS SignaLink Wireless Kit

SKU: 3008040
  • Model Number - WSS
  • Item Number - 3008040
  • UL 864 10th edition and ULC S527 Listed
  • Fully supervised wireless communication bridge between all dry contact devices
  • 2.4 GHz communication format
  • Transmitter works on any dry contact product not listed as explosion proof
  • Receiver provides dry contact output, compatible with any fire panel/fire alarm system
  • Receiver does not require resetting or silencing, allowing it to beinstalled remotely from the FACP
  • Eliminates the need for extensive wiring/conduits
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,416.00
Web Price: $989.00
Save to my Wish List
Product Details

The Potter SignaLink Bridge is a fully supervised wireless bridge designed to be attached to any non-explosion-proof dry contact sprinkler monitoring devices. It removes the need to hard wire sprinkler devices to each other, and operates on a 2.4 GHz frequency. Devices are able to communicate with each other up to a maximum of 800’. All enclosures are weather and UV resistant polycarbonate. There are no external antennas. The antenna is incorporated into the circuit board of each device.


Specifications


WTX-M Transmitter

  • Conduit Connection - ½” NPT male
  • Enclosure - UV and Impact resistant Polycarbonate
  • Environmental Limitations - Indoor/Outdoor NEMA 4 / IP66 -40°F to 150°F (-40°C to 66°C)
  • Max Circuit Current - 28uA
  • Max Circuit Voltage - 3 VDC
  • Power Requirement - Two AA size Energizer 1.5 volt Lithium Iron/Disulfide battery model L91, 3000 mAh
  • Reference Level - Maximum Ambient noise level allowed: -37 dBm
  • Service Use - NFPA 13, 13D, 13R and 72
  • Weight - 0.5 lbs (0.23 KG)

WRX-R Receiver

  • Conduit Connection - Opening for 1/2” conduit, terminals for 12-22 AWG wires
  • Contact Rating - Common Alarm/Supervisory Relay: 1A at 30 VDC
  • Enclosure - UV and Impact resistant Polycarbonate
  • Environmental Limitations - Indoor/outdoor use with standard smoked cover. Indoor use only with optional clear cover. NEMA 4 (IP66) -40°F to 150°F (-40°C to 66°C)
  • Power Requirement - 24VDC at 55mA Normal, 75mA in Alarm
  • Reference Level - Maximum Ambient noise level allowed: -37dBm
  • Service Use - NFPA 13, 13D, 13R, 72
  • Weight - 0.75lbs (0.34KG)

3008040 Specifications PDF