The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL1RDV Altronix 16 Channel 3Amp 24VDC or 4Amp 12VDC Access Control Power Supply/Charger with Controller

SKU: MAXIMAL1RDV
  • Eight (8) or Sixteen (16) independently controlled PTC protected 12VDC and/or 24VDC outputs
  • Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state PTC protected outputs
  • Thermal and short circuit protection with auto reset
  • Supervision
    • AC Fail
    • Low Battery
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the outputs
  • Fire Alarm disconnect input options : a) Normally open (NO) or normally closed (NC) dry contact input, b) Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,086.00
Online Price: $776.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Maximal Rack Mount Series units distribute and switch power to access control systems and accessories. They convert a 220VAC 50/60Hz input into eight (8) or sixteen (16) independently controlled 12VDC and/or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.


Specifications


Input

  • Voltage - 220VAC (working range 198VAC - 256VAC), 50/60Hz
  • Fusing - Varies, see Reference Chart

Outputs

  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, see Reference Chart
  • Other - Overvoltage protection Filtered and regulated outputs

Back-up Battery

  • Type - Sealed lead acid or gel type
  • Charging current - 0.7A
  • Fuse Rating - 15A @ 32VDC, (Maximal1RHDV and Maximal1RDV); Maximal3RHDV, Maximal3RDV, and Maximal33RDV do not have a battery fuse
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the outputs

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts

Indicators (LED)

  • Input - Illuminated ON/Reset Switch
  • Output - Individual Output Status LEDs located on the front panel

Physical and Environmental

  • Dimensions (H x W x D) - 3.25” x 19.125” x 8.5” (82.55mm x 485.78mm x 215.9mm)
  • Product Weight - 10.7 lbs. (4.85 kg)
  • Shipping Weight - 12.7 lbs (5.76kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 12VDC : 25 BTU/Hr, 24VDC: 37 BTU/Hr