The cart is empty.
Dealers. First. Always.
DWG

MAXFIT16A4 Altronix 16 Channel 4Amp 12VDC or 4Amp 24VDC Access Control Power Supply in UL Listed NEMA 1 Indoor 16.5” W x 20.5” H x 6.25” D Steel Electrical Enclosure

SKU: MAXFIT16A4
  • 19 Gauge steel enclosure
  • Ample knockouts accommodating either 3/4” or 1” conduits for convenient access
  • Cam lock and keys are included
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,014.00
Web Price: $724.00
Save to my Wish List
Product Details

Altronix ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes.Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally indepen-dent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.


Specifications


Input


  • Voltage
    • 12 to 24 VAC or VDC operation (setting not required), 0.4A @ 12V, 0.2A @ 24V current consumption with all relays energized
    • Main fuse is rated at 10A
  • Trigger Inputs
    • Four (4) Access Control System trigger inputs: a) Four (4) normally open (NO) inputs
    • b) Four (4) open collector sink inputs
    • c) Any combination of the above
  • Input Options
    • a) One (1) common power input (board and lock power)
    • b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power)

Outputs

  • Four (4) independently controlled 2.5A outputs
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs
  • b) Four (4) dry form “C” 5A rated relay outputs
  • c) Any combination of the above
  • Four (4) auxiliary power outputs (unswitched)
  • Output ratings - Output fuses are rated 2.5A each
  • Note - Total output current is determined by the power supply, not to exceed a maximum of 10A total

Indicators (LED)

  • Red LEDs - Outputs are triggered (relays energized)
  • Green LED - FACP disconnect is triggered

Agency Listings

  • UL - Access Control : UL294
  • cUL - General Signaling Equipment Evaluated to CSA Standard C22.2 No.205-M1983

Physical and Environmental

  • Dimensions (H x W x D) - 5.175” x 3.36” x 1.25” (131.4mm x 85.3mm x 31.8mm)
  • Product Weight - 0.35 lbs. (0.16 kg)
  • Shipping Weight - 0.45 lbs. (0.2 kg)
  • Operating Temperature - 0ēC to 49ēC (32ēF to 120ēF)
  • Storage Temperature - -20ēC to 70ēC (-4ēF to 158ēF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 12VAC or VDC : 2 BTU/Hr, 24VAC or VDC: 3 BTU/Hr

BC750 Specifications

  • Capacity - Fits up to four (4) 12VDC/12AH batteries
  • Dimensions (H x W x D) - 20.5” x 16.5” x 6.25” (520.7mm x 419.1mm x 158.8mm)
  • Product Weight - 19.4 lb. (8.8 kg)
  • Shipping Weight - 24.8 lb. (11.25 kg)

ACM4 Specifications PDF

BC750 Specifications PDF