The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL3DV Altronix 16 Channel 6Amp 24VDC or 6Amp 12VDC Access Control Power Supply in UL Listed NEMA 1 Indoor 19” W x 26” H x 6.25” D Steel Electrical Enclosure

SKU: MAXIMAL3DV
  • Sixteen (16) independently controlled (16) Fail-Safe and/or Fail-Secure power outputs
  • Sixteen (16) auxiliary power outputs (unswitched)
  • Output PTCs are rated @ 2.5A
  • Filtered and electronically regulated outputs
  • Supervision
    • AC Fail
    • Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options
    • a) Normally open (NO) or normally closed (NC) dry contact input
    • b) Polarity reversal input from FACP signaling circuit
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,438.00
Online Price: $1,027.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Maximal Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) independently controlled 12VDC or 24VDC PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.


Specifications


Input

  • Voltage - 220VAC (working range 198VAC - 256VAC), 50/60Hz
  • Fusing - Varies, see Reference Chart

Outputs

  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, see Reference Chart
  • Protection - PTC 2.5A
  • Auxiliary - 3.5A (unswitched)
  • Other - Overvoltage protection Filtered and regulated outputs

Back-up Battery

  • Capacity - 12AH / 12VDC (up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC Maximal3DV does not have a battery fuse
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs
  • EOL - 10K Resistor

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts

Indicators (LED)

  • Input - 220VAC is present
  • DC Output - Powered
  • Battery - Discharged or not connected
  • Relays - Individual LEDs indicate outputs are triggered (relays energized)
  • FACP - Indicates FACP disconnect is triggered

Agency Listings

  • CE - European Conformity

Physical and Environmental

  • Dimensions (H x W x D) - 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm)
  • Product Weight - 42.3 lbs. (19.17 kg)
  • Shipping Weight - 46.3 lbs. (21.00 kg)
  • Operating Temperature - 0ēC to 49ēC (32ēF to 120ēF)
  • Storage Temperature - -20ēC to 70ēC (-4ēF to 158ēF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 12VDC : 31 BTU/Hr, 24VDC: 67 BTU/Hr

MAXIMAL3DV Specifications PDF

MAXIMAL3DV Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In