MAXFIT78APS Altronix AL1024ULXB2 P/S/ACM8/VR6/PDS8

SKU: MAXFIT78APS
  • Altronix AL1024ULXB2 UL Listed Sub-Assembly power supply/charger
  • Converts 115VAC 60Hz input into a single 24VDC non power-limited output
  • Offers a suite of features that includes AC fail supervision, battery presence, and low battery supervision
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,266.00
Web Price: $904.00
Save to my Wish List
Product Details

AL1024ULXB2 Specifications


Input

  • Voltage - 115VAC 60Hz, 4.2A max
  • Fusing - 5A / 250V

Output

  • Voltage - 24VDC (UL 1481)
  • Current - 8A continuous supply current with 10A supply current during alarm (UL 1481). 24VDC @ 10A (UL 294)
  • Other - Short circuit and thermal overload protection Filtered and regulated

Back-up Battery

  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32V
  • Failover - Upon AC loss, instantaneous.

Supervision

  • AC Failure - Form "C" contacts
  • Battery - Form "C" contacts

Indicators (LED)

  • Input - 115VAC is present
  • DC Output - Powered
  • Battery - Discharged or not connected

Agency Listings

  • UL
    • Access Control - UL294
    • Burglar Alarm - UL 603
    • Fire Alarm - UL 1481
  • cUL
    • Signal Equipment - CSA C22.2 No.205-M1983

Physical and Environmental

  • Dimensions (H x W x D) - 8.4" x 4.5" x 1.9" (213.4mm x 114.4mm x 49.7mm).
  • Product Weight - 1.15 lbs. (0.52 kg).
  • Shipping Weight - 1.45 lbs. (0.0.66 kg)
  • Temperature
    • Operating - 0°C to 49°C (32°F to 120°F)
    • Storage - -20°C to 70°C (-4°F to 158°F)
  • Relative Humidity - 85% +/-5%.
  • BTU/Hr (approx.) - 123 BTU/Hr

ACM8 Specifications


Input

  • Voltage
    • 12 to 24 VAC or VDC operation (setting not required), 0.6A @ 12V, 0.3A @ 24V current consumption with all relays energized
    • Main fuse is rated at 10A
  • Trigger Inputs - Eight (8) Access Control System trigger inputs:
    • Eight (8) normally open (NO) inputs
    • Eight (8) open collector sink inputs
    • Any combination of the above
  • Input Options
    • One (1) common power input (board and lock power)
    • Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power)

Outputs

  • Eight (8) independently controlled 2.5A outputs:
    • Eight (8) Fail-Safe and/or Fail-Secure power outputs
    • Eight (8) dry form “C" 5A rated relay outputs
    • Any combination of the above
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings - Output fuses are rated 3.5A each
  • Note - Total output current is determined by the power supply, not to exceed a maximum of 10A total

Indicators (LED)

  • Red LEDs - Outputs are triggered (relays energized)
  • Green LED - FACP disconnect is triggered

Agency Listings

  • UL
    • Access Control - UL294
  • cUL
    • General Signaling Equipment Evaluated to CSA Standard C22.2 No.205-M1983

Physical and Environmental

  • Enclosure Dimensions (H x W x D) - 8" x 4" x 0.75" (203.2mm x 114.3mm x 19.1mm)
  • Product Weight - 0.65 lbs. (0.29 kg)
  • Shipping Weight - 0.85 lbs. (0.39 kg)
  • Temperature
    • Operating - 0°C to 49°C (32°F to 120°F)
    • Storage - -20°C to 70° C (-4°F to 158°F)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 4 BTU/Hr

VR6 Specifications


Input/Output

  • Voltage Range - 24VDC @ 1.75A = Output: 5VDC @ 6A, 24VDC @ 3.5A = Output: 12VDC @ 6A

Output

  • 5VDC or 12VDC regulated output
  • Output rating 6A max.
  • Surge suppression

Indicators (LED)

  • Input - Indicates input voltage is present
  • Output - Indicates normal operating condition

Agency Listings

  • UL/cUL - UL 294 6th Edition - Access Control System Units, ULC- S319 - Electronic Access Control Systems

Physical and Environmental

  • Dimensions (L x W x H) - 5.375” x 3” x 1” (136.5mm x 76.2mm x 25.4mm)
  • Product Weight - 0.4 lbs. (0.18 kg)
  • Shipping Weight - 0.5 lbs. (0.23 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr (approx.) - 5VDC: 15 BTU/Hr, 12VDC: 37 BTU/Hr

PDS8 Specifications


Input

  • Voltage Range - 5VDC to 24VDC, up to 10A each or16VAC to 28VAC, 60Hz, up to 10A each,20A total input
  • Main Fuse Rating - 10A.

Outputs

  • Fuse protected outputs rated @ 3A per output,non power-limited. Total output 20A max

Outputs Ratings

  • 4.8 - 24 VDC or 15.8 - 28 VAC

Indicators (LED)

  • DC Output - Eight (8) individual output LEDs

Agency Listings

  • UL/cUL - UL 294 6th Edition - Access Control System Units, ULC-S319 - Electronic Access Control Systems.

Physical and Environmental

  • Dimensions (L x W x H) - 5.375” x 3” x 1” (136.5mm x 76.2mm x 25.4mm)
  • Product Weight - 0.25 lbs. (0.11 kg)
  • Shipping Weight - 0.3 lbs. (0.14 kg)
  • Operating Temperature - 0°C to 49° (32°F to 120°F)
  • Storage Temperature - -20°C to 70°C (-4°F to 158°F)
  • Relative Humidity - 85% +/-5%

AL1024ULXB2 Specifications Sheet

ACM8 Specifications Sheet

VR6 Specifications Sheet

PDS8 Specifications Sheet