The cart is empty.
Dealers. First. Always.
DWG

FPO250/250-6M8PNLXE12M LifeSafety Power Mercury 24 Door 20 Amp 12VDC 2 Managed and 48 Class Distribution Outputs Access Control Power Supply in UL Listed Indoor 36" W x 48" H x 8" D Electrical Enclosure

SKU: FPO250/250-6M8PNLXE12M
  • 120 or 230 VAC input
  • 12 and 24 VDC outputs
  • On board Fire Alarm Interface
  • Continuous and resettable DC
  • Forty eight managed control - class 2 at 2.5A each
  • Live voltage / current reporting
  • Remote battery load testing
  • Output power cycling and abnormal operation alert
More details...
Availability: 2 to 3 Week Lead Time
MSRP Price: $7,438.00
Web Price: $4,959.00
Save to my Wish List
Product Details

MCLASS Unified Power Systems combine FlexPower power modules alongside Mercury Security access hardware in one compact and secure UL Listed solution. This unit is a 12V and 24V DC dual voltage managesd access power system.

Six M8 lock control modules provide forty eight access control inputs capable of voltage or dry contact activation, and forty eight outputs programmable for failsafe / failsecure operation at either 12 or 24 VDC and controlled by the integrated fire alarm interface circuit on the FPO.


Specifications


Input Power

  • Input 120/230 VAC 50/60 Hz | 600 Watts (2.35A)
  • Overload and short circuit protection
  • Over temperature protection
  • Polarized AC power supply disconnect

Output Power

  • FPO250 X 2: 12V/20A or 24V/10A | 250 Watts
  • Outputs: Continuous (DC1) Resettable (DC2)
  • 48 managed outputs, fused at 3A each
  • 120 mV output voltage ripple
  • System Efficiency: 87% | System BTU Rating: 218 BTU/Hr

Battery Charging

  • Independent built-in 2A charger for sealed lead-acid or gel type batteries
  • Microprocessor dual rate charging of 12 or 24V battery sets
  • Charges up to 80Ah battery sets within UL limit
  • Automatic switchover to standby battery when AC fails
  • Zero voltage drop when switched over to battery backup

Supervision

  • AC Fault (form "C" contacts)
  • System Fault (form "C" contacts) may be triggered by low/no battery, short to earth ground and power supply failure or blown fuse

Visual Indicators

  • AC input, DC1 and DC2 output
  • System fault
  • AC fault
  • Short to earth ground
  • Reverse battery polarity
  • Fire Alarm Input activated
  • M8: DC outputs and fault

Regulatory Compliance Mercury/LSP Joint Listing

  • UL294, UL603, UL1076, ULC S318, ULC S319 CSA C22.2 #107.1, CSA 22.2 #60950
  • FCC Part 15, Subpart B, CE

Enclosure Dimensions

  • Size: 48.00H x 36.00W x 8.00D in. (122.00 x 91.00 x 20.30 cm) | Weight: 120 lbs

Access Panel Mounting

  • LP1502, LP4502, LP2500, MR50, MR52, MR16, LNL-500, 1100, 1200, 1320, 2000, 2220, 3300

FPO250/250-6M8PNLXE12M Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In