The cart is empty.
Dealers. First. Always.
DWG

SLE-MAXA-CBTF-C Napco StarLink MAX Commercial Burglar/Residential LTE Cellular Alarm Communicator - White Metal Enclosure - Powered by Transformer - AT&T Network

SKU: SLE-MAXA-CBTF-C
  • Power limited output to the StarLink communicator PC board 12V input terminals
  • Battery connection red and black flying leads
  • Monitored battery charging and Active battery test circuits
  • StarLink communicator trouble input (from StarLink communicator PC board PGM1 terminal to detect StarLink communicator trouble)
  • Requires a sealed lead acid min 4AH / max 7AH battery for minimum 24-hour standby time (maximum charge current 200mA)
  • Trouble relay output (C, N/O and N/C terminals) to wire to a panel zone dedicated to "CAT-M1 Trouble" (dry contacts). Remove jumper "J2" to isolate common from ground
  • Green AC ON LED visible from the exterior housing
  • Yellow TROUBLE LED on PC board. Flashes signify:
    • One flash: AC fail / brownout (2 hour delay)
    • Two flashes: Low battery
    • Three flashes: Charging circuit trouble
    • Four flashes: StarLink communicator trouble
More details...
MSRP Price: $466.58
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

The StarLink Connect model SLE-MAXA-CBTF-C (AT&T Certified) and model SLE-MAXV-CBTF-C (Verizon Certified) are multi-function Commercial / Residential Burglary and Residential Fire alarm communicators and supervised system interface modules.


Specifications


Electrical Ratings for +12V

  • Input Voltage - 10-15VDC (Regulated power-limited output from control panel). Do NOT connect to full-wave rectified (FWR) power
  • Input Current - SLE-MAXA-CBTF-C and SLE-MAXV-CBTF-C standby current

Electrical Ratings for 120VAC, 60Hz For Models with Power Supply

  • Input Voltage - 120VAC nominal
  • Input Current - 150mA maximum
  • Maximum Charging Current - 200mA
  • For Wi-Fi add 45mA (use 7AH battery)

Electrical Ratings for the IN 1 Burg/Fire Input

  • Input Voltage - 9-15VDC
  • Maximum Input Current - Up to 2mA from control panel supply circuit

Electrical Ratings for IN 2 and IN 3

  • Maximum Loop Voltage - 15VDC max
  • Maximum Loop Current - 1.2mA
  • End of Line Resistor (EOLR) Value - 10K

Electrical Ratings for 3 PGM Outputs

  • Open Collector Outputs - Maximum Voltage 3V when active; 15V maximum when not active
  • Maximum PGM Sink Current - 50mA (up to 15VDC)

Physical (W x H x D)

  • Metal Housing - 11½ x 9½ x 3½" (29.2 x 24.1 x 8.9cm)
  • Mounting - Metal housing includes two keyhole slots for wall mounting (see measurements in WI2458)

Environmental

  • Operating Temperature - 0°C - 49°C (32°F - 120°F)
  • Humidity - Maximum 93% Non-Condensing
  • Environment - Indoor / dry location use only

SLE-MAXA-CBTF-C Specifications PDF