The cart is empty.
Dealers. First. Always.
DWG

AL1012ULACM Altronix 8 Output Fused Power Supply/Charger w/ Controller and Enclosure 12VDC @ 10 Amp

SKU: AL1012ULACM
  • Eight (8) independently controlled outputs
  • Output options: Eight (8) Fail-Safe and/or Fail-Secure power outputs; Eight (8) form “C” 5A rated relay outputs; Any combination of the above
  • Eight (8) auxiliary power outputs (unswitched)
  • Output fuses are rated @ 3.5A
  • Filtered and electronically regulated outputs
  • Supervision: - AC Fail, - Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
  • UL Listed in the U.S. and Canada
  • Lifetime Warranty / Made in the U.S.A
More details...
Ordering Notes: Dealers Only
MSRP Price: $626.00
Online Price: $447.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Altronix AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACMCB is a PTC protected version of this unit.


Specifications


Input

  • Voltage Range - 115VAC, 60Hz
  • Fusing - Varies, see Reference Chart

Outputs

  • Voltage - 12VDC or 24VDC, see Reference Chart
  • Current - Varies, depending on the model
  • Protection - Fused 3.5A
  • Auxiliary - 3.5A (unswitched)
  • Other - Overvoltage protection. Filtered and regulated outputs

Back-up Battery (not included)

  • Capacity - 12AH / 12VDC (1 or 2 within enclosure).18AH / 12VDC (requires larger "J" enclosure).40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC AL600ULACM(J) does not have a battery fuse./li>
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Latching or non-latching, individually selectable for any or all of the eight (8) outputs

Supervision

  • AC Failure - Form "C" contacts
  • Battery - Form "C" contacts

Indicators (LED)

  • Input - 115VAC is present
  • DC Output - Powered.
  • Battery - Discharged or not connected
  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered

Agency Listings

  • All Models
    • UL
      • UL294 - Access Control System Units
    • cUL
      • CSA C22.2 No.205 - Signal Equipment

Physical and Environmental

  • Dimensions (H x W x D) - 15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm)
  • Product Weight - 10.7 lbs. (4.85 kg)
  • Shipping Weight - 12 lbs. (5.44 kg)
  • Temperature
    • Operating - 0°C to 49°C (32°F to 120°F)
    • Storage - -20°C to 70°C (-4°F to 158°F)
  • Relative Humidity BTU/Hr. (approx.)
    • 12VDC - 61
    • 24VDC - N/A

AL1012ULACM Spec Sheet

AL1012ULACM Installation Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900