The cart is empty.
Dealers. First. Always.
DWG

STRIKEIT1 Altronix Dual Panic Device Power Controller

SKU: STRIKEIT1
  • Altronix StrikeIt1 operates up to two (2) 24VDC panic hardware devices simultaneously.
  • It is designed to handle the high current surge panic hardware locking devices demand.
  • Each lock output has an adjustable relock delay timer.
  • It controls a pair of doors simultaneously or independently control two individual doors.
  • It has a follower relay for each output to trigger external relays, ADA push plate switches, etc.
More details...
Ordering Notes: Dealers Only
MSRP Price: $708.00
Web Price: $506.00
Save to my Wish List
Product Details

Specifications


Input

  • Voltage - 115VAC, 60Hz, 6.3A. Two (2) NO trigger inputs.
  • Fusing - Input fuse rating6.3A.

Outputs

  • Power options - Two (2) 20VDC to 26.4VDC individually controlled lock outputs for applications with battery back-up. 24VDC for applications without battery back-up (US applications only). Current rating 15A for 300ms, 0.75A continuous supply current, 5V holding voltage with 20VDC to 26.4VDC initial 100ms pulse. Maximum total 5V holding current of both outputs is 0.74A.
  • One (1) 20VDC to 26.4VDC for applications with battery back-up, 24VDC for applications in US not requiring battery back-up. Auxiliary output rated @ 0.75A continuous supply current (Not affected by FACP trigger).
  • One (1) 12VDC filtered regulated auxiliary output rated @ 0.75A in alarm, 0.5A stand-by current (Not affected by FACP trigger). Two (2) follower form “A" SPST relay outputs rated @ 0.6A/28VDC. Relays energize while input is closed.
  • Two (2) delayed follower Normally Open relay outputs rated @ 0.6A/28VDC. Delay time is selectable 0.5 seconds or 1 second. Energized duration is 1 second.
  • Trouble relay output indicating low DC output voltage.

Back-up Battery

  • Type - Sealed lead acid or gel type.
  • Failover - Upon AC loss, instantaneous.
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.

Fire Alarm Disconnect

  • Normally Closed FACP trigger input.
  • Programmable Fire Alarm Disconnect options - Removes power to outputs and disables delayed follower relays, Connects power to lock outputs and enables delayed follower relays.

Indicators (LED)

  • AC Power (Green) - Input voltage is present.
  • Trigger Input (Red) - Panic device status/trouble.
  • FAI (Red) - FACP disconnect.
  • Battery (Red) - Low battery.

Agency Listings

  • UL - UL294 (Access Control System Units).
  • cUL - ULC-S319 - Access Control Unit Power Supply. Class 1.
  • CSFM - California State Fire Marshal Approved.

Physical and Environmental

  • Dimensions (H x W x D) - 13.5" x 13" x 3.25" (342.9mm x 330.2mm x 82.6mm)
  • Product Weight - 6.25 lbs. (2.83 kg).
  • Shipping Weight - 7.15 lbs. (3.24 kg).
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF).
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF).
  • Relative Humidity - 85% +/-5%.
  • BTU/Hr. (approx.) - 36 BTU/Hr.

STRIKEIT1 Specifications PDF