POE30U-560G-HT Phihong 30W Power over Ethernet Adapter High Power Single Port Injector High Temperature
|
|
|
SKU: POE30U-560G-HT
- Features:
- Fully Compliant detection, disconnect and voltage control IEEE802.3af
- UNH IOL Tested
- Diagnostic LEDs
- Full Protection OCP, OVP
- Non-Vented Case
- Gigabit Compatible
- Cisco Legacy Support
- Applications:
- IP Telephones
- Security Cameras
- Wireless Network Access Points
- IP Print Servers
- Blue Tooth Access Points
More details...
|
DWG Dealer Price : ---
Dealers - click here to set up your dealer account today.
Existing DWG Customers - Log In to view your current dealer pricing.
|
|
|
POE30U-560G-HT Phihong 30W Power over Ethernet Adapter High Power Single Port Injector High Temperature
|
|
|
|
Product Details
|
- Model Number - POE30U-560GHT
- Input Voltage Range - 85 to 264VAC
- AC Input Voltage Rating - 100 to 240VAC
- AC Input Frequency - 100 to 240VAC
- AC Input Current -
- 15A (RMS) maximum for 115VAC
- 20A (RMS) maximum for 230VAC
- Leakage Current -
- 0.25mA maximum for 264VAC 50Hz for input to PE
- 3.5mA maximum for 264VAC 50Hz for input to output
- AC Inrush Current -
- 15A (RMS) maximum for 115VAC
- 20A (RMS) maximum for 230VAC
- Total Output Power - 30W at 56V DC
- Regulation - Line and Load 54-57V DC under all conditions
- Efficiency - 75% (typical) at maximum load, and 120VAC 60Hz
- Temperature -
- Operation : -20 to +55°C
- Non-operation : -40 to +85°C
- Humidity : -40 to +85°C
- Isolation Test -
- Primary to Secondary: 4242VDC for 1 minute 10mA
- Primary to F.G.: 2121VDC for 1 minute
- Output to F.G.: 2121VDC
- Immunity -
- ESD: EN61000-4-2. Level 3
- RS: EN61000-4-3. Level 2
- EFT: EN61000-4-4. Level 2
- Surge: EN61000-4-5. Level 3
- CS: EN61000-4-6. Level 2
- Voltage Dips: EN61000-4-11
- Harmonic: EN61000-3-2
- EMC - FCC Part 15 Class B, EN55022 Class B
- Insulation Resistance -
- Primary to Secondary: >10M OHM 500VDC
- Primary to Field Ground: >10M OHM 500VDC
- Over Voltage/Current, Short Circuit Protection - Output can be shorted permanently without damage
- Input Connector - IEC320 inlet 3 pin
- Output Connector -
- Hold-up Time - 16mS min. and 120VAC at maximum load
- DC Offset - No data degradation with DC imbalance 18mA per min.
- Transient O/P Voltage Protection - 60V maximum zener clamp
- IEEE 802.3at Interoperability - UNH Interoperability report available upon request
- Safety Approvals - cUL/UL, CE, Korea K, C-Tick, CCC, SAA, S-Jet, IRAM
POE30U-560GHT Specifications PDF
|
|
|