The cart is empty.
Dealers. First. Always.
DWG

POE80U-560G Phihong 80W Power over Ethernet Adapter High Power Single Port Injector

SKU: POE80U-560G
  • Features:
    • Fully Compliant detection, disconnect and voltage control IEEE802.3af
    • Single Source 4 Pair Power Current Sharing
    • Diagnostic LEDs
    • Full Protection OCP, OVP
    • Non-vented case
    • 10/100/1000 Gigabit Compatible
    • Broken Wire Detect
    • Built-in mounting brackets
More details...
MSRP Price: $216.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details
  • AC Input Voltage Range - 90 to 264VAC
  • AC Input Voltage Rating - 100 to 240VAC, 47-63Hz
  • AC Input Voltage Range - 85 to 264VAC
  • AC Input Current - 2.0A (RMS) maximum for 90VAC, 1.2A (RMS) maximum for 240VAC
  • Leakage Current - 3.5mA maximum @ 254VAC 60Hz
  • AC Inrush Current - 50A (RMS) maximum for 115VAC, 50A (RMS) maximum for 230VAC
  • Total Output Power - 80W
  • DC Offset - No Data degradation with DC imbalance 18mA per min.
  • Ripple and Regulation - 100mV maximum
  • Efficiency - 75% (typical) at maximum load, and 120VAC 60Hz
  • Hold Up Time - 10mS minimum 120VAC and maximum load
  • Transient O/P Voltage Protection - 60V maximum at switch on and off at any point on AC line phase
  • Temperature -
    • Operation: -40 to +55°C
    • Non-Operation: -50 to +85°C
  • Humidity Operation - 5 to 90%
  • EMC - FCC Part 15 Class B, EN55022 Class B
  • Immunity -
    • ESD: EN61000-4-2. Level 3
    • RS: EN61000-4-3. Level 2
    • EFT: EN61000-4-4. Level 2
    • Surge: EN61000-4-5. Level 3
    • CS: EN61000-4-6. Level 2
    • Voltage Dips EN61000-4-11
    • Harmonic: EN61000-3-2
  • Isolation Test -
    • Primary to Secondary: 4242 VDC for 1 minute
    • Primary to Field Ground: 2121VDC for 1 minute
    • Output to Field Ground: 2121VDC
  • IEEE 802.3af/at Interoperability - UNH Interoperability report available upon request
  • Insulation Resistance - Primary to Secondary: >10M OHM 500VDC/Primary to Field Ground: >10M OHM 500VDC
  • Detection - 12.5kohm detection resistor value required to turn on full power 4 pair power.
  • Short Circuit Protection - Outputs equipped with short circuit protection and overload protection as per 802.3af specifications except max average pair current is 0.72A, Peak 1.4A per pair. The output can be shorted permanently without damage.
  • Input Connector - IEC320 inlet 3 pin
  • Weight - 4.25 lb
  • Size - 203mm x 108 x 63
  • Warranty - 1 Year

POE80U-560G Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In