The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL3 Altronix 16 Output Fused Power Supply/Charger w/ Controller and Enclosure 12VDC or 24VDC @ 5.5Amp

SKU: MAXIMAL3
  • Sixteen (16) independently controlled outputs.
  • Sixteen (16) auxiliary power outputs (unswitched).
  • Output fuses are rated @ 3.5A.
  • Filtered and electronically regulated outputs.
  • Supervision - AC Fail, Battery Fail and Battery Presence.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Fire Alarm disconnect input options - Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
  • UL Listed in the U.S. and Canada.
  • Lifetime Warranty / Made in the U.S.A.
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,438.00
Online Price: $1,027.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Maximal3 distributes and switches power to access control systems and accessories. They convert a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc.


Specifications


Input

  • Voltage - 115VAC, 60Hz.
  • Fusing - Varies, See Reference Chart.

Outputs

  • Voltage - 12VDC and/or 24VDC, see Reference Chart.
  • Current - Varies, see Reference Chart.
  • Protection - Fused 3.5A.
  • Auxiliary - 2.5A (unswitched).
  • Other - Overvoltage protection, Filtered and regulated outputs.

Back-up Battery(not included)

  • Capacity - 12AH / 12VDC (up to 4 within enclosure). 40 AH / 65 AH (requires separate enclosure).
  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC Maximal3 does not have a battery fuse.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the outputs.

Supervision

  • AC Failure - Form "C" contacts.
  • Battery - Form "C" contacts.

Indicators (LED)

  • Input - 115VAC is present.
  • DC Output - Powered.
  • Battery - Discharged or not connected.
  • Relays - Individual LEDs indicate outputs are triggered (relays energized).
  • FACP - Indicates FACP disconnect is triggered.

Agency Listings

  • UL - UL294 - Access Control System Units.
  • cUL - C22.2 No.205-M1983 General Signaling Equipment
  • CSFM - California State Fire Marshall Approved.

Physical and Environmental

  • Dimensions (H x W x D) - 26" x 19" x 6.25" (660.4mm x 482.6mm x 158.75mm).
  • Product Weight - 30.8 lb. (14.0 kg)
  • Shipping Weight - 37.8 lb. (17.2 kg)
  • Operating Temperature - 0°C to 49°C (32°F to 120°F).
  • Storage Temperature - -20°C to 70°C (-4°F to 158°F).
  • Relative Humidity - 85% +/-5%.
  • BTU/Hr. (approx.) - 12VDC - 31, 24VDC - 67

MAXIMAL3 Specifications PDF

MAXIMAL3 Installation Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In