The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL5 Altronix 16 Output Fused Power Supply/Charger w/ Controller and Enclosure 12VDC @ 9Amp

SKU: MAXIMAL5
  • Sixteen (16) independently controlled outputs.
  • Output options: Sixteen (16) Fail-Safe and/or Fail-Secure power outputs, Sixteen (16) form “C” 5A rated relay outputs, Any combination of the above
  • Sixteen (16) auxiliary power outputs (unswitched).
  • Output fuses are rated @ 3.5A.
  • Filtered and electronically regulated outputs.
  • Supervision: AC Fail, Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries.
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,454.00
Online Price: $1,039.00
Save to my Wish List

DWG Dealer Price : ---


Dealers - click here to set up your dealer account today.

Existing DWG Customers - Log In to view your current dealer pricing.



Previous Item   Next Item
Product Details

Maximal Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 115VAC, 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail-Safe/ Fail-Secure power outputs may be converted to dry form “C” contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc.


Specifications


Input

  • Voltage - 115VAC, 60Hz
  • Fusing - Varies, See Reference Chart.

Outputs

  • Voltage - 12VDC and/or 24VDC, see Reference Chart.
  • Current - Varies, see Reference Chart
  • Protection - Fused 3.5A.
  • Auxiliary - 2.5A (unswitched)
  • Other - Overvoltage protection. Filtered and regulated outputs

Back- up Battery (not included)

  • Capacity - 12AH / 12VDC (up to 4 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type.
  • Fuse Rating - 15A @ 32VDC Maximal3 does not have a battery fuse
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Latching or non-latching, individually selectable for any or all of the sixteen (16) outputs.

Supervision

  • AC Failure - Form “C” contacts.
  • Battery - Form “C” contacts.

Indicators (LED)

  • Input - 115VAC is present.
  • DC Output - Powered
  • Battery - Discharged or not connected.
  • Relays - Individual LEDs indicate outputs are triggered (relays energized)
  • FACP - Indicates FACP disconnect is triggered.

Agency Listings

  • UL - UL294 - Access Control System Units
  • cUL - C22.2 No.205-M1983 - General Signaling Equipment
  • CSFM - California State Fire Marshall Approved.

Physical and Environmental

  • Dimensions (H x W x D) - 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm).
  • Product Weight - 31.8 lb. (14.4 kg)
  • Shipping Weight - 38.85 lb. (17.6 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF).
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF).
  • Relative Humidity - 85% +/-5%.
  • BTU/Hr. (approx.) - 12VDC - 55

MAXIMAL5 Specification PDF

MAXIMAL5 Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In