The cart is empty.
Dealers. First. Always.
DWG

MAXIMAL1RD Altronix 16 Output PTC Rack Mount Power Supply/Charger w/ Controller 12VDC @ 4Amp or 24VDC @ 3Amp

SKU: MAXIMAL1RD
  • Eight (8) or Sixteen (16) independently controlled fuse protected 12VDC and/or 24VDC outputs.
  • Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected outputs
  • Thermal and short circuit protection with auto reset
  • Supervision - AC Fail, Low Battery
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the outputs
  • Fire Alarm disconnect input options - Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries.
  • Instantaneous transfer to stand-by batteries.
  • Lifetime Warranty / Made in the U.S.A
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the outputs.
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,086.00
Web Price: $776.00
Save to my Wish List
Product Details

Maximal Rack Mount Series units distribute and switch power to access control systems and accessories. They convert a 115VAC 50/60Hz input into eight (8) or sixteen (16) independently controlled 12VDC and/or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc.


Specifications


Input

  • Voltage - 115VAC, 50/60Hz.
  • Fusing - Varies, See Reference Chart.

Outputs

  • Voltage - 12VDC and/or 24VDC, see Reference Chart.
  • Current - Varies, see Reference Chart.
  • Protection - PTC 2.0A.
  • Other - Overvoltage protection, Filtered and regulated outputs.

Back-up Battery(separate enclosure is required)

  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC (Maximal1RHD and Maximal1RD); Maximal3RHD, Maximal3RD, and Maximal33RD do not have a battery fuse.
  • Failover - Upon AC loss, instantaneous.

Fire Alarm Disconnect

  • Supervised - Latching or non-latching, individually selectable for any or all of the outputs.

Supervision

  • AC Failure - Form “C” contacts.
  • Battery - Form “C” contacts.

Indicators (LED)

  • Input - Illuminated ON/Reset Switch.
  • Output - Individual Output Status LEDs located on the front panel.

Physical and Environmental

  • Dimensions (H x W x D) - 3.25” x 19.125” x 8.5” (82.55mm x 485.78mm x 215.9mm).
  • Product Weight - 10.7 lbs. (4.85 kg)
  • Shipping Weight - 12.7 lbs (5.76kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF).
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF).
  • Relative Humidity - 85% +/- 5%.
  • BTU/Hr. (approx.) - 12VDC - 25, 24VDC - 37, 12VDC and 24VDC - N/A

MAXIMAL1RD Specifications PDF

MAXIMAL1RD Manual


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In