The cart is empty. 6 Total: $22,466.00
Dealers. First. Always.
DWG

MAXIMAL75FK3 Altronix 1 Channel 10Amp 12VDC Access Control Power Supply in UL Listed NEMA 1 Indoor 19” W x 26” H x 6.25” D Steel Electrical Enclosure

SKU: MAXIMAL75FK3
  • Altronix eFlow102NB UL Listed Sub-Assembly power supply/charger converts a 120VAC, 60Hz input into a single 12VDC output
  • It also offers a suite of features that includes fire alarm disconnect, overvoltage protection, and low power disconnect which prevents deep discharge of stand-by batteries
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,692.00
Web Price: $1,209.00
Save to my Wish List
Product Details

eFlow102NB Specifications


Input

  • Voltage - 120VAC, 60Hz, 3.5A max
  • Fusing - 5A / 250V

Output

  • Voltage - 12VDC
  • Current - 10A continuous max
  • Auxiliary - Power-limited @ 1A (unswitched)
  • Other - Overvoltage protection. Filtered and regulated outputs

Back-up Battery (not included)

  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching
  • EOL - 10K Resistor

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge

Indicators (LED)

  • Input - 120VAC is present
  • DC Output - Powered

Agency Listings


UL

  • Access Control - UL294
  • Burglar Alarm - UL603
  • Fire Alarm - UL1481

cUL

  • Burglar Alarm - ULC-S318-96
  • Access Control - ULC-S319-05
  • Signal Equipment - CSA C22.2 No.205

Physical and Environmental

  • Dimensions (H x W x D) - 7.5” x 4.6” x 1.75” (190.5 mm x 116.8 mm x 44.5 mm)
  • Product Weight - 0.85 lbs. (0.39 kg)
  • Shipping Weight - 1.0 lbs. (0.45 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 61 BTU/Hr

eFlow104NB Specifications


Input

  • Voltage - 120VAC, 60Hz, 4.5A max
  • Fusing - 6.3A / 250V

Output

  • Voltage - 24VDC
  • Current - 10A continuous max
  • Auxiliary - Power-limited @ 1A (unswitched)
  • Other - Overvoltage protection. Filtered and regulated outputs

Back-up Battery (not included)

  • Type - Sealed lead acid or gel type
  • Fuse Rating - 15A @ 32VDC
  • Failover - Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised - Latching or non-latching
  • EOL - 10K Resistor

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge

Indicators (LED)

  • Input - 120VAC is present
  • DC Output - Powered

Agency Listings


UL

  • Access Control - UL294
  • Burglar Alarm - UL603
  • Fire Alarm - UL1481

cUL

  • Burglar Alarm - ULC-S318-96
  • Access Control - ULC-S319-05
  • Signal Equipment - CSA C22.2 No.205

Physical and Environmental

  • Dimensions (H x W x D) - 8.25” x 4.56” x 1.5” (209.5 mm x 115.8 mm x 38.1 mm)
  • Product Weight - 1.1 lbs. (0.5 kg)
  • Shipping Weight - 1.25 lbs. (0.57 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 123 BTU/Hr

ACM8 Specifications


Input

  • Voltage
    • 12 to 24 VAC or VDC operation (setting not required), 0.6A @ 12V, 0.3A @ 24V current consumption with all relays energized
    • Main fuse is rated at 10A
  • Trigger Inputs
    • Eight (8) Access Control System trigger inputs
    • a) Eight (8) normally open (NO) inputs
    • b) Eight (8) open collector sink inputs
    • c) Any combination of the above
  • Input Options
    • a) One (1) common power input (board and lock power)
    • b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power)
  • Outputs
    • Eight (8) independently controlled 2.5A outputs
    • a) Eight (8) Fail-Safe and/or Fail-Secure power outputs
    • b) Eight (8) dry form “C” 5A rated relay outputs
    • c) Any combination of the above
    • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings
    • Output fuses are rated 3.5A each
    • Note - Total output current is determined by the power supply, not to exceed a maximum of 10A total

Indicators (LED)

  • Red LEDs - Outputs are triggered (relays energized)
  • Green LED - FACP disconnect is triggered

Agency Listings

  • UL - UL294 : Access Control System Units
  • cUL: - General Signaling Equipment Evaluated to CSA Standard C22.2 No.205-M1983

Physical and Environmental

  • Dimensions (H x W x D) - 8” x 4” x 0.75” (203.2mm x 114.3mm x 19.1mm)
  • Product Weight - 0.65 lbs. (0.29 kg)
  • Shipping Weight - 0.85 lbs. (0.39 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 4 BTU/Hr

eFlow102NB Specifications PDF

eFlow104NB Specifications PDF

ACM8 Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900
Connect with us on Social Media   Facebook   Instagram   Twitter   Linked In