UPS-OL3000R Middle Atlantic Premium Online Series UPS Backup Power 2RU 3000VA

SKU: UPS-OL3000R
  • Permanent connection to the battery for zero transfer time eliminating system disruptions and guaranteeing maximum uptime
  • Complete isolation and conditioning of output power with double conversion topology providing the cleanest power possible
  • Reduced ambient noise with quiet variable speed fans
  • Longest run time available in this form factor with the capability to add up to 10 expansion battery packs
  • Front accessible, hot-swappable batteries to eliminate downtime related to UPS power maintenance
  • Pure sine wave output waveform automatically corrects over-voltage and under-voltage conditions
  • Non-critical load shedding
  • EMI/RFI filtering for clean power of connected equipment
More details...
UPC: 656747272592
Ordering Notes: Dealers Only
MSRP Price: $5,146.00
Web Price: $4,631.40
Save to my Wish List
Product Details

Rackmount Online Uninterruptible Power Supply (UPS) shall be Middle Atlantic Products model # UPS-OL__ R (refer to chart). Unit shall measure 19.00” W x 3.50” H x __” D and occupy 2 rackspaces. UPS shall have a rear mounting range of 20.69” to 36.19” and not require more than one person to mount. UPS shall have a minimum usable depth of __” (refer to chart). Unit shall operate on 120 VAC/60Hz. Unit shall have a nominal output of 120V. Unit shall have a capacity of __ VA and __ W (refer to chart). Unit shall have (_) NEMA 5- __ receptacles on the rear of the unit (refer to drawing). Unit shall have a priority outlet bank consisting of _ outlets dedicated to ensure maximum run time of critical components. Unit shall have a non-critical outlet bank consisting of _ outlets dedicated to load shedding (refer to drawing). Unit shall be IP enabled when used with optional IP Expansion card, model# UPS-OLIPCARD. Rackmount UPS shall include a 10’ power cord with NEMA __ (refer to chart) plug. UPS shall have surge suppression that utilizes a clean line-to-neutral design that does not pass noise contamination to ground. Rackmount UPS shall have a hot swappable battery that allows for a __ minute run time at half load and a __ (refer to chart) minute run time at full load. Rear of unit shall have inputs that allow for the installation of up to __ additional hot swappable batteries (refer to chart). Rackmount UPS shall meet the EU RoHS Directive 2011/65/EU. Rackmount UPS shall utilize Middle Atlantic Power Manager software. Rackmount UPS shall be warrantied to be free from defects in materials and workmanship under normal use and conditions for a period of 3 years; battery shall be warrantied for a period of 2 years. Rackmount UPS shall be UL listed to US and Canadian safety requirements and FCC/IC Class A or B.


Specifications


CONFIGURATION

  • Capacity (VA) - 3000VA
  • Capacity (Watts) - 2700W

INPUT

  • Cord Length and Plug Type - 10ft, NEMA L5-30P
  • Input Voltage Range - 100~125Vac
  • Input Frequency Range - 50 / 60Hz
  • Input Power Factor - 0.99
  • Cold Start - Yes

OUTPUT

  • Output Waveform - Sine wave
  • Output Voltage (regulated) - 100, 110, 115, 120, 125Vac (Configurable) ±2%
  • Output Frequency - 50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz
  • Transfer Time - 0ms
  • Rated Power Factor - 0.9
  • Harmonic Distortion - THD < 3% at Linear Load, < 5% at Non-linear Load
  • Crest Factor - 3:01
  • ECO Mode Voltage Regulation - ±10%, ±15% (Configurable)
  • UPS Outlets - 6) NEMA 5-20R, (1) L5-30R
  • Thermal Dissipation - 1116 BTU/hr
  • Audible Noise (@1.5m) - < 50dBA

PROTECTION

  • Surge Protection - IEC 61000-4-5 Level 3
  • Phone / Network Protection - RJ11/RJ45 (One In/One Out)
  • Overload Protection - Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
  • Short Circuit Protection - UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection

BATTERY

  • Specifications - (6) 12V/9AH
  • Full Load Runtime (estimated) - 4min
  • Half Load Runtime (estimated) - 11min
  • Recharge Time (Typically) - 5 hours for 0-100% Capacity; 4 hours for 0-90% Capacity
  • Sealed, Maintenance Free - Yes
  • Hot-Swappable - Yes

STATUS INDICATORS

  • LCD Screen - Multi-Function LCD Readout that Supports: (19) Types of Read Out, (22) Types of Function Setting, (5) Event Logs
  • LED Indicators - Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
  • Audible Alarms - Battery Mode, Battery Low, Overload, UPS Fault

ENVIRONMENT

  • Operating Temperature - 32º to 104º F ( 0º to 40º C)
  • Operating Relative Humidity - 0 to 90% Non-Condensing

MANAGEMENT

  • On-Device Features - Self-Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery
  • Connectivity Ports - (1) Serial Port (RS232), (1) USB Port, (1) Relay Out
  • Expansion Slot - (1) Expansion Slot for optional remote management cards (With optional UPS-OLIPCARD)

SOFTWARE

  • Power Management Software - Middle Atlantic Power Manager Software

PHYSICAL

  • Net Weight - 68.2lbs (31kg)

SAFETY

  • Conformance Approvals - UL and FCC
  • RoHS - RoHS Compliant

UPS-OL3000R Specifications PDF