The cart is empty.
Dealers. First. Always.
DWG

EFLOW104NK2Q Altronix 10Amp 24VDC Power Supply in UL Listed NEMA 1 Indoor 13” W x 13.5” H x 3.25” D Steel Electrical Enclosure

SKU: EFLOW104NK2Q
  • 8 fuse or PTC protected outputs
  • Management interface for up to two (2) eFlow power supply/chargers
  • Two (2) network controlled Form “C” relays
  • Management interface software included (USB flash drive)
  • Includes interface cables
  • Lifetime Warranty / Made in the U.S.A
  • Three (3) monitored input triggers
  • UL Listed in the U.S. and Canada
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,194.00
Web Price: $853.00
Save to my Wish List
Product Details

Altronix VR6 Voltage Regulator converts a 24VDC input into a regulated 5VDC or 12VDC selectable output at up to 6A supply current. It reduces the cost of adding an additional power supply to achieve 24VDC and 12VDC or 5VDC simultaneously.


VR6 Specifications


Input/Output

  • Voltage Range - 24VDC @ 1.75A = Output: 5VDC @ 6A, 24VDC @ 3.5A = Output: 12VDC @ 6A

Output

  • 5VDC or 12VDC regulated output
  • Output rating 6A max
  • Surge suppression

Indicators (LED)

  • Input - Indicates input voltage is present
  • Output - Indicates normal operating condition

Agency Listings


UL/cUL

  • UL 294 6th Edition - Access Control System Units
  • ULC-S319 - Electronic Access Control Systems

Physical and Environmental

  • Dimensions (H x W x D) - 5.375” x 3” x 1” (136.5mm x 76.2mm x 25.4mm)
  • Product Weight - 0.4 lbs. (0.18 kg)
  • Shipping Weight - 0.5 lbs. (0.23 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120ºF)
  • Storage Temperature - -20ºC to 70ºC (-4ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 5VDC: 15 BTU/Hr, 12VDC: 37 BTU/Hr

LINQ8PD Specifications


Input

  • Voltage/Current - 12VAC - 28VAC/12.5A each or 2VDC - 28VDC/12.5A each
  • Note - Do not connect AC and DC simultaneously to INP1 and INP2

Outputs

  • Output Ratings - Eight (8) fused outputs rated 3A (LINQ8PD)
  • Other - Power output(s) can be locally or remotely controlled, Surge suppresion

Status Monitoring

  • Power Supply(ies) output voltage and load
  • Voltage and load of each output
  • FACP trigger and reset status
  • Unit temperature (Celsius)
  • Power Supply AC and Battery status
  • Battery health

Indicators (LED)

  • Bat Local - Charging current status
  • FACP - Triggered / Released
  • Input - Input signal
  • Out1 - Out8 - Output status

Reporting

  • Windows Dashboard Alert messages
  • E-mail notifications
  • Event Log tracks history

Programming Features

  • Power Supply(ies) voltage and load limits (High/Low)
  • FACP trigger type (wet or dry-N.O./N.C.)
  • Input Function (FACP reset/tamper)
  • Output Reset Trigger (N.O./N.C.)
  • Battery Monitor Configuration
    • Battery condition (Low/Normal/Missing)
    • Service Date
  • Configurable Output Relay(s)
  • Individual Output Configuration
    • Device ID
    • Voltage and Current Limits (High/Low)
    • FACP Trigger Setting (latching/non-latching/inactive)
    • Battery Backup

Fire Alarm Interface

  • Supervised FACP disconnect (Latching or Non-Latching)
  • FACP reset (N.C. or N.O.)

Physical and Environmental

  • Dimensions (L x W x H) - 5.5” x 3.625” x 0.96” (139.7mm x 92.07mm x 24.38mm)
  • Product Weight - 0.4 lbs. (0.18kg)
  • Shipping Weight - 0.7 lbs. (0.32kg)
  • Operating Temperature - -20°C to 49°C (-4°F to 120.2°F)
  • Storage Temperature - -30ºC to 70ºC (-22ºF to 158ºF)
  • Relative Humidity - 85% +/-5%

LINQ2 Specifications


Input

  • Current consumption 100mA to be subtracted from the eFlow power supply’s output
  • [COM1 & COM0] ports are currently disabled, reserved for future use
  • Visit www.altronix.com for latest software updates

Outputs

  • Power output(s) can be locally or remotely controlled

Status Monitoring

  • AC status
  • Output current draw
  • Unit’s temperature
  • DC output voltage
  • Low Battery/Battery presence detection
  • Input trigger state change
  • Output (relay and power supply) state change

Programming

  • Battery service date indication
  • Programmable via USB or web browser
  • Automated timed events: - Control output relays and power supply via flexible timing parameter

Reporting

  • Programmable dashboard notifications
  • E-mail notification selectable by event
  • Event log tracks history (100+ events)

Indicators (LED)

  • Blue LED - Power ON

Agency Listings


UL

  • UL 294 - Access Control System Units
  • UL 603 - Power Supplies for Use with Burglar-Alarms Systems
  • UL 1481 - Power Supplies for Fire Protective Signaling Systems

cUL

  • ULC-S318-96 - Power Supplies for Burglar Alarm Systems Also suitable for Access Control
  • ULC-S318-05 - Power Supplies for Electronic Access Control Systems

Physical and Environmental

  • Dimensions with Mounting Bracket (W x L x H) - 3.65” x 3.25” x 0.96” (92.7mm x 82.55mm x 24.4mm)
  • Product Weight - 0.4 lbs. (0.18 kg)
  • Shipping Weight - 0.7 lbs. (0.32 kg)
  • Operating Temperature - 0ºC to 49ºC (32ºF to 120.2ºF)
  • Storage Temperature - -30ºC to 70ºC (-22ºF to 158ºF)
  • Relative Humidity - 85% +/-5%
  • Operating Altitude - -304.8 to 3,048m (-1,000 to 10,000 ft.)

VR6 Specifications PDF

LINQ8PD Specifications PDF

LINQ2 Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900