AL1024NKA8QM Altronix 8 Fused 6Amp 24VDC or 6Amp 12VDC Access Control Power Supply in UL Listed NEMA 1 Indoor 12” W x 15.5” H x 4.5” D Steel Electrical Enclosure – Gray

SKU: AL1024NKA8QM
  • Unit provides 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power)
  • Short circuit and overvoltage protection
  • Supervision: AC Fail; Battery Fail and Battery Presence
  • Fire alarm disconnect
  • Bi-colored LEDs provide visual verification of voltage on each output
  • Stackable sub-assemblies save valuable space
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
  • Eight (8) independently controlled outputs
More details...
Ordering Notes: Dealers Only
MSRP Price: $1,392.00
Web Price: $994.00
Save to my Wish List
Product Details

Altronix AL1024NKA8QM converts a 115VAC 60Hz input into eight (8) fuse protected outputs. Outputs are individually selectable, providing 12VDC or 5VDC up to 6A and/or 24VDC up to 10A (240W total power) for access control panels, door locks, and ancillary devices. Power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO), normally closed (NC) dry trigger input, or wet output from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. AL1024NKA8QM will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple LINQ8ACM modules. This feature allows you to distribute the power over more outputs for larger systems. Built-in LINQTM Network Power Management facilitates monitoring, reporting and control of power/diagnostics.


Specifications


Power Supply (AL1024ULXB2)


Input

  • Voltage - 115VAC 60Hz, 4.2A max
  • Fusing - 5A/250V

Outputs

  • Voltage - 24VDC
  • Current - 10A @ 24VDC continuous max
  • Other - Overvoltage protection, Filtered and regulated

Back-up Battery

  • Capacity - 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
  • Type - Sealed lead acid or gel type
  • Failover - Upon AC loss, instantaneous

Supervision

  • AC Failure - Form “C” contacts
  • Battery - Form “C” contacts

Indicators (LED)

  • Input - 115VAC is present
  • DC Output - Powered
  • Battery - Discharged or not connected

Voltage Regulator (VR6)


Input

  • Voltage - 24VDC from AL1024ULXB2

Output

  • Voltage - 12VDC
  • Current - 6A continuous
  • Other - Surge suppression

Indicators (LED)

  • Input - 24VDC is present
  • Output - Powered

Network Access Power Controller (LINQ8ACM)


Input

  • Voltage - 24VDC from AL1024ULXB2 and 12VDC from VR6
  • Input Fuses - 15A/32V

Outputs

  • Fuse protected outputs rated @ 2.5A per output, non power-limited
  • Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing
  • Output Fuses - 3A/32V

Programming Features

  • Eight (8) Programmable Outputs
    • Fail-safe, fail-secure or auxiliary outputs
    • Input controlled or manually controlled through software
    • High (over) and low (under) voltage and current monitoring by output
    • Multiple outputs may be programmed to be triggered by a single input
    • Battery back-up by output
  • Eight (8) Programmable Trigger Inputs
    • Normally open (NO)
    • Normally colsed (NC)
    • Open collector sink inputs
    • Wet Input (5VDC - 24VDC) with 10k resistor
    • Any combination of the above
  • Other Programmable Trigger Inputs

    • Monitor power supply(ies) input for voltage and currect limits (high/low)
    • Input and output current calibration
    • Programmable timer events
    • Programmable user levels
    • Enable or disable alerts by type
    • Programmable alert reporting delay

Fire Alarm Disconnect

  • Supervised - Inactive, latching or non-latching, individually selectable for any or all of the eight (8) outputs
  • EOL - 10K Resistor

LED Indicators

  • Green AC LED - indicates AC trouble condition
  • Green BAT LED - indicates battery trouble condition
  • Green FACP LED - indicates FACP disconnect is triggered
  • Flashing Blue Heartbeat LED - indicates network connection
  • Individual OUT1 - OUT8 Red LEDs - indicate outputs are triggered
  • Out1 - Out8 - Bi-colored LEDs indicate 12 or 24VDC

Agency Listings

  • CE - European Conformity
  • All components of this kit are UL Listed sub-assemblies
  • Please refer to the corresponding Sub-Assembly Installation Guides for further information

Physical and Environmental

  • Dimensions (H x W x D) - 15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm). Enclosure accommodates up to two (2) 12AH/12VDC batteries
  • Product Weight - 9.4 lb. (4.26 kg)
  • Shipping Weight - 10.5 lb. (4.76 kg)
  • Operating Temperature - 0ēC to 49ēC (32ēF to 120ēF)
  • Storage Temperature - -20ēC to 70ēC (-4ēF to 158ēF)
  • Relative Humidity - 85% +/-5%
  • BTU/Hr. (approx.) - 123 BTU/Hr

AL1024NKA8QM Specifications Sheet