The cart is empty.
Dealers. First. Always.
DWG

ADAC422D American Dynamics Matrix Distribution Panel - Power Supply Sold Separately

SKU: ADAC422D
  • Compatible with American Dynamics® MegaPower matrix switcher/controller systems, Intellex® digital video management systems, and RS-422 converter (RCSN422)
  • Amplifies RS-422/RS-485 communications signals for multipoint dome control
  • Supports home-run, daisy-chain, star, and junction box (J-Box) wiring topologies to accommodate any type or size system
  • Accommodates home-run dome wiring via 16 output ports
  • Install at head end or remote locations
  • Rack (2U) or wall mountable
  • Space-saving design allows mounting at either the front or rear of an electronics rack, facing in or out
  • Surge suppression provided on all data and power connections
More details...
MSRP Price: $1,245.00
Online Price: $1,245.00
Save to my Wish List
Product Details

The RS-422/RS-485 distribution panel amplifies either a RS-422 or RS-485 communications signal. With 16 outputs, the panel can accommodate home-run wiring, multiple daisy-chained links to SpeedDome programmable dome cameras or J-Boxes.
The panel also includes inputs for multiple MegaPower CPUs allowing you to maintain control from both the primary and backup CPUs, thereby providing a redundant solution. In addition, the panel can also accept RS-232 communication signals from MegaPower CPU or Intellex® digital video management systems where RS-232 is required. For diagnostic control you can monitor signal activities on each channel.


Specifications


Physical

  • Dimensions (L x W x D) - 481 x 87 x 34 mm (18.9 x 3.4 x 1.3 in)
  • Body Length - 445 mm (17.6 in)
  • Weight - 0.75 kg (1.66 lbs)
  • Mounting - Standard electronic rack (2U), EIA310-D (19 in) IEC 60297-1 (482.6 mm) Wall mount

Electrical

  • Power Source - External power module Certified limited power source required Multiple panels may be connected to the maximum VA rating of the transformer
  • Input - 12 to 30 V DC or AC Isolation not required
  • Frequency - 50-60 Hz
  • Power Consumption - 8 VA
  • Diagnostic Indicators
    • Power On/Heartbeat - Green LED
    • Host A, B, C Data Detect - Yellow LED
    • Channel 1-16 Data Detect - Yellow LED
    • Channel 1-16 Line Status Test Switch - Red/Green LED
  • Protection - Certified limited power source NEC Class 2 Internal primary current fuse Inrush limiting DC isolation
  • Cable to Transformer- 5 m (16.5 ft) 18 AWG, 3-conductor
  • Input Connector - Euro-style 3-pin removable plug 5.06 mm (0.2 in) terminal block
  • Surge Protection
    • Transient Voltage Suppressors (TVS) - 60 V, 250 A, 1.5 J
    • Gas Discharge Tube Impulse Rate - 10 kA
  • Design Tolerance
    • Input Voltage Minimum - 11 V DC or AC without dropout
    • Input Voltage Maximum - >36 V DC or AC
    • Input Frequency - 47 to 63 Hz
    • Allowable Dropout - 150 ms

Surge Protection

  • Transient Voltage Suppressors (TVS)
    • Breakdown Voltage - 8.5 V ±20%
    • Peak Current - 40 A
    • Capacitance - 1200 pf at 1 kHz
  • Gas Discharge Tube Impulse Rate
    • DC Breakdown Voltage - 90 V DC
    • Insulation Resistance - 10,000 mΩ
    • Capacitance - 2 pf max
    • 8/20 μsec Impulse Discharge Current - 10 kA
    • Ten 8/20 μsec Impulse Discharge Current - 5 kA

Environmental

  • Operating Temperature - 10° to 50°C (14° to 122°F)
  • Storage Temperature - 40° to 70°C (-40° to 158°F)
  • Relative Humidity - 0 to 95% noncondensing

Regulatory

  • EMC
    • 47 CFR, Part 15
    • EN 50130-4; EN55022
    • EN61000-3-2; EN61000-3-3
    • CISPR 22
  • Safety - UL/IEC/EN/CSA C22.2.60950-1
  • Environmental
    • RoHS 2002/95/EC
    • WEEE 2002/96/EC
    • IP code X0

ADAC422D Specifications PDF


Product Reviews

Write your own review

 

Rate this product:


DWG - 800 Shames Drive , Westbury , NY 11590 , USA - 516-933-4900