ED6200RMN1 Minuteman Endeavor Series 6kVA Online Redundant UPS System 208V Input/Output

SKU: ED6200RMN1
  • Simple parallel installations (no extra PCB required)
  • Full digital signal processor
  • Easy-to-set user personalization
  • Intelligent self diagnosis
  • Smart fan control
  • Emergency Power Off (EPO) function
  • True double conversion on-line technology
  • High input Power Factor and low voltage THD
More details...
MSRP Price: $7,750.00
Online Price: $7,750.00
Save to my Wish List
Product Details

The Main Control module takes only 2U in rack height and provides 208/240V input and output. Input is hardwired to the unit. The main control module has a LCD/LED display. Each control module must have at least one battery back (EDBP6000RM). Parallel functions are available for up to 208V 24kVA. N+1 full-redundancy function is available up to 18kVA for 208/240V applications and 6kVA for 120V applications. Optional receptacle boxes are available for 6kVA units.


Specifications


  • Topology - Double Conversion On-Line, True Sine Wave
  • Maximum power capacity - 6000VA/4200Watts

Input

  • Voltage window - 160~280VAC*
  • Frequency - 50/60 Hz ± 5Hz autosensing
  • Number of phases • Surge energy rating - Single (1Ø 2W +G) • 1050J
  • Power factor correction - ≥98% at 100% Linear Load

Output

  • Voltage window - 200/208/240VAC selectable 120V with transformer
  • Voltage adjustment / Voltage regulation - 0%; ±1%; ±2%; ±3% /±2%
  • Capacity - 6000VA/4200W
  • Rated power factor - 0.7 Lagging
  • Wave form - Sine Wave
  • Frequency Regulation - ±0.2%(Free Running) unless synchronized to utility
  • Transfer time - 0ms
  • Efficiency - > 87% line mode
  • Autonomy full/half - 9 min/23 min
  • Voltage THD - <3% at 100% Linear Load

Battery

  • Type - Sealed non-spillable lead acid maintenance free 12V/7.2Ah
  • Quantity / Voltage / Recharge Time - 20pcs / 240VDC / 8 hours to 90%

Display

  • Status On LED + LCD - Line mode, backup mode, ECO mode, bypass, battery low, battery bad/disconnect, overload, and transferring with interruption & UPS fault.
  • Readings on LCD - Input voltage, input frequency, output voltage, output frequency, load percentage, battery voltage & internal temperature.
  • Self-diagnostics - Upon power-on, front panel setting & software control

Alarms

  • Audible and Visual - Line failure, battery low, transfer to bypass, system fault conditions

Physical

  • Dimensions- WxDxH- in (mm) - 17.3x3.4x26.7in (440x88x680mm) - (UPS Module)
  • Input/output connection / External battery connection - Hardwired / Plug and Play
  • Net weight(kg) - 53.0 lb/ 24kg(UPS Module)
  • Battery pack net weight - 120.0 lb (54.2 kg)
  • Battery Bank Dimensions - Convertible(Rack/Tower) / 17.3x5.2x26.7in (440x132x680mm) (3U)
  • Isolation transformer dimensions/ Net weight - 17.3x3.4x 26.7in (440x88x680mm) - (2U) / 93 lb (42 kg)

Environment

  • Operating temperature - 32ºF to 104ºF (0ºC to 40ºC)
  • Altitude / Humidity - 0~2000m up to 104ºF (40ºC), 3000m up to 95ºF (35ºC) / 90% RH Maximum, Non-Condensing
  • Noise - <50dB (at 1 meter)

Computer Interface

  • Interface type - Standard RS-232 Interface
  • Communication slots - 2nd RS-232 **, USB *** Relay Contact, SNMP/WEB Card, etc.

Safety Conformance

  • Safety and approvals - UL 1778, cUL (CSA 2.2 no. 107.1), CE (EN62040-1-1)
  • EMC - CE (EN62040-2, EN61000-3-2, EN61000-3-3), FCC Class A

ED6200RMN1 Specifications PDF